Analyzing Signals from a Primary Winding of a Locomotive Transformer with Three Types of Wavelet-Based Transforms
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2017, Vol 41, Issue 41
Abstract
The paper is concerned with the analysis of in-stantaneous values and evaluation of certain power quality indices corresponding to phase currents and voltages ac-quired from the primary winding of a locomotive trans-former. Representative data sets acquired during all operat-ing regimes (acceleration, constant speed, normal and re-spectively regenerative braking) were analyzed. Firstly the background noise was estimated by using a wavelet thrash-ing tree considering a wavelet mother with a short filter. Specific computational aspects related to the use of the Sta-tionary Wavelet Transform were presented and it was used to evaluate the instantaneous values of the fundamental harmonic, respectively the distorting residue. Discrete Wavelet Transform was used for 3 situations to deal with time-frequency localization of deviations from stationarity. A nodal analysis was also made with an original implemen-tation of the Wavelet Packet Transform in a special situa-tion, when the deviation from stationarity nearby the right edge prevents the use of DWT. Excepting the thrashing tree, the wavelet mother used in all transformations relied on a filter of length 40 due to the good properties of selectivity relative to the harmonics’ energies. All methods were used to evaluate the 3 major root mean square values (for fun-damental frequency, for distorting residue and total). The results yielded by different methods were compared. A good convergence of methods was noticed. Explanations for the small differences are suggested.
Authors and Affiliations
Ileana-Diana Nicolae, Radu-Florin Marinescu, Petre-Marian Nicolae, Diana-Cristina Marinescu
Analysis of a Step-Down DC-DC Converter: Linear Versus Nonlinear Circuit
This paper aims to investigate the step-down dc-dc converters from circuit analysis viewpoint. These converters have a lot of utilizations, including different applications in power energy conversion domain, being...
Indirect Current Control Algorithm Implementation and Validation, for Active Filtering Using Constant Switching Frequency Hysteresis Controllers
The aim of this paper is the implementation and the experimental validation of a constant switching frequency hysteresis current controller as a part of an active filtering system control algorithm, based on the indirect...
The Load Influence on the Diagnosis of the Three-Phase Rectifier by Using the Analytical Model Method
For the operation of the static power converters, the experience of an expert is absolutely necessary for competitive operation. Minor faults or defects of the elements of the static power converters can lead to ravag...
The Synchronous Fundamental dq Frame Theory Application for the Active Filtering
One of the methods that have been used for the analysis of three phase systems is the rotating fundamental dq frame. Although it was especially used for the analysis of three phase machines, because it is a time...
COMPUTER AIDED ANALISYS OF INDUCTION MOTOR
Sometimes the digital control system of an electrical machine has some parameters that are unknown or they are known, but can vary in time. The control circuits with self-tuning controllers are using parameter identifica...