Assessment of Electrical Heart Axis: Comparison of Hexaxial Reference System with Unipolar and Bipolar Lead Based Formula

Journal Title: International Journal of Pharma Research and Health Sciences - Year 2016, Vol 4, Issue 2

Abstract

Introduction: The assessment of electrical heart axis (EHA) has important applications towards interpretation of electrocardiogram (ECG) of patients in both clinical and epidemiological studies. Objective: The present study was conducted to assess the EHA from net voltages of QRS complexes in bipolar and augmented unipolar leads. Methods: The calculation of EHA in the frontal plane were determined using different formulae: , , , and using hexaxial reference system. Results: Comparable results were obtained with , , and for the prediction of normal EHA and Left Axis Deviation (LAD) with formula methods showing highest similarity with the hexaxial system. However, none of the formula was suitable for the prediction of Right Axis Deviation (RAD) and Extreme Axis Deviation (EAD).The EHA obtained from the leads after applying correction did not differ significantly from the values without correction The EHA values calculated using four formula methods different non-significantly except the and formula in the prediction of normal EHA. Conclusion: For all practical purposes, and formulae may be used for rapid EHA computation of normal heart axis and LAD. These two formulae may be tested for designing nomogram of normal EHA and LAD with large number of cases. Newer formula needs to be developed for the rapid calculation of RAD and EAD.A single formula for the pr

Authors and Affiliations

Keywords

Related Articles

Development and Evaluation of Mucoadhesive Microspheres of Irbesartan

Aim: Mucoadhesive microspheres has been accepted as a process to achieve controlled drug delivery by prolonging the residence time of the dosage form at the site of absorption thereby improving and enhancing the bioavail...

Nephroprotective Effect of Ficus Dalhousiae Miq Leaf Methanolic Extract in Albino Wistar Rats

The aim of the present study was to evaluate nephroprotective effect of Ficus dalhousiae miq leaf methanolic extract (FDLME) in Albino wistar rats.The nephrotoxicity was induced by gentamicin and Acetaminophen. Wistar al...

Analysis of the Appropriateness and Cost of Antibiotics Usage in Outpatients at Emergency Department

Unnecessary usage of antibiotics in patients at Emergency Department (ED) is one of important issues resulting in a number of adverse consequences, namely: the occurrence of antibiotics resistance, longer medication peri...

Quantification of Total Phenolic Content, HPLC Analysis of Flavonoids and Assessment of Antioxidant and Anti-haemolytic Activities of Hibiscus rosasinensis L. Flowers in vitro

Objective: Hibiscus rosa sinensis Linn. is widely available and employed by practitioners of natural health for variety of ailments. The present study aimed to investigate total phenolic content (TPC), analysis of flavon...

Design and Characterization of Periodontal Films of Moxifloxacin Hydrochloride by Using Basil Seed Gum

The objective of this research was to design and evaluate site specific Periodontal strips containing Moxifloxacin hydrochloride (MH) in a biocompatible carriers which has excellent activity against wide range of microor...

Download PDF file
  • EP ID EP325633
  • DOI -
  • Views 91
  • Downloads 0

How To Cite

(2016). Assessment of Electrical Heart Axis: Comparison of Hexaxial Reference System with Unipolar and Bipolar Lead Based Formula. International Journal of Pharma Research and Health Sciences, 4(2), -. https://europub.co.uk/articles/-A-325633