Can Evolutionary-based Brain Map Be Used as a Complementary Diagnostic Tool with fMRI, CT and PET for Schizophrenic Patients?
Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 2
Abstract
Objective: In this research, a new approach termed “evolutionary-based brain map” is presented as a diagnostic tool to classify schizophrenic and control subjects by distinguishing their electroencephalogram (EEG) features. Methods: Particle swarm optimization (PSO) is employed to find discriminative frequency bands from different EEG channels. By deploying the energy of those selected frequency bands for different channels within each time frame (window) on the scalp geometry, a sort of two dimensional point along with their values are created; by applying Lagrange interpolation, an image can be constructed. By averaging the images belonging to successive time frames, an evolutionary-based brain map is created. Results: In this study, twenty subjects from each group voluntarily participated and their EEG signals were caught from 20 channels. The energy of selected bands for different channels is arranged in a feature vector for each time frame and applied to Fisher linear discriminant analysis (FLDA) resulting in 83.74% diagnostic accuracy between the two groups. The achieved result by the proposed method was much higher than applying the energy of standard EEG bands (delta, theta, alpha, beta and gamma) to the same classifier which just provided 77.04% accuracy. Applying T-test to the achieved results supports the supremacy of the proposed method as an automatic powerful diagnostic tool. Conclusion: The proposed brain map is capable of highlighting the same physiological and anatomical changes which are observed in fMRI, PET and CT as differentiable indicators between controls and schizophrenic patients.
Authors and Affiliations
R Boostani, M Sabeti
Design and Production of Two-piece Thyroid-neck Phantom by the Concurrent Use of Epoxy Resin and Poly(methyl methacrylate) Soft Tissue Equivalent Materials
The aim of this report is to present a new two-piece thyroid-neck phantom produced by the concurrent use of epoxy resin and poly(methyl methacrylate) (PMMA: plexiglass) soft tissue equivalent materials. Accordingly, mass...
Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured...
Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA
Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Electron specific absorbed fractions (SAF) values have had vital role in the assessment of absorbed dose. In past stu...
Martian Residents: Mass Media and Ramsar High Background Radiation Areas
Considering current controversies regarding the health effects of low doses of ionizing radiation, study of the high background radiation areas such as Ramsar, Iran can help scientists better evaluate the validity of lin...
Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode
Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis o...