Design and Production of Two-piece Thyroid-neck Phantom by the Concurrent Use of Epoxy Resin and Poly(methyl methacrylate) Soft Tissue Equivalent Materials
Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 2
Abstract
The aim of this report is to present a new two-piece thyroid-neck phantom produced by the concurrent use of epoxy resin and poly(methyl methacrylate) (PMMA: plexiglass) soft tissue equivalent materials. Accordingly, mass attenuation coefficients of the epoxy resin and the plexiglass compounds were obtained from simulation (NIST XCOM 3.1) and measurements (practical dosimetry) and compared to those related to human soft tissue (ICRU 44). The thyroid-neck phantom and thyroid gland dimensions were derived from scientific references and the atlas of human anatomy, respectively. The thyroid phantom was designed by CATIA V5R16 software and produced by the epoxy resin compound by three-dimensional printer. Other organs were designed by ProNest software and made by the plexiglass sheets by CNC laser cutting machine. The mass attenuation coefficients for the epoxy resin (50 keV- 20 MeV) and the plexiglass (0- 20 MeV) were comparable to human soft tissue (ICRU 44), all with standard relative deviation beneath 5%. In addition, the SPECT images indicated the similarity between human thyroid tissue and its phantom. In conclusion, this study proves the feasibility and reliability of epoxy resin application in the production of two-piece thyroid-neck phantom. This phantom can be applied in the calibration of gamma camera systems, dosimetry and gamma spectrometry in the nuclear medicine field.
Authors and Affiliations
M. Karimi, H. Mostaghimi, S. F. Shams, A. R. Mehdizadeh
Modelling Tumor-induced Angiogenesis: Combination of Stochastic Sprout Spacing and Sprout Progression
Background: Angiogenesis initiated by cancerous cells is the process by which new blood vessels are formed to enhance oxygenation and growth of tumor. Objective: In this paper, we present a new multiscale mathematical mo...
An Investigation to Determine an Optimum Protective Garment Material in Nuclear Medicine
Aim: The aim of this study is to find an optimum material to protect garment for protection against 99Tcm radionuclide. Materials and Methods: Monte Carlo simulation code was applied to investigate radiation attenuation...
Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual extern...
Evaluation the FLAIR Sensitivity and DWI Post-inject in Comparison with Delayed Enhancement T1w for Better Detection of Active MS Lesions
Background: Multiple sclerosis (MS) is a chronic, typically progressive and most common autoimmune disease which damaged the central nervous system. According to the reports in 2008, this disorder has affected 2 and 2.5...
A New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This stud...