Design and Production of Two-piece Thyroid-neck Phantom by the Concurrent Use of Epoxy Resin and Poly(methyl methacrylate) Soft Tissue Equivalent Materials

Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 2

Abstract

The aim of this report is to present a new two-piece thyroid-neck phantom produced by the concurrent use of epoxy resin and poly(methyl methacrylate) (PMMA: plexiglass) soft tissue equivalent materials. Accordingly, mass attenuation coefficients of the epoxy resin and the plexiglass compounds were obtained from simulation (NIST XCOM 3.1) and measurements (practical dosimetry) and compared to those related to human soft tissue (ICRU 44). The thyroid-neck phantom and thyroid gland dimensions were derived from scientific references and the atlas of human anatomy, respectively. The thyroid phantom was designed by CATIA V5R16 software and produced by the epoxy resin compound by three-dimensional printer. Other organs were designed by ProNest software and made by the plexiglass sheets by CNC laser cutting machine. The mass attenuation coefficients for the epoxy resin (50 keV- 20 MeV) and the plexiglass (0- 20 MeV) were comparable to human soft tissue (ICRU 44), all with standard relative deviation beneath 5%. In addition, the SPECT images indicated the similarity between human thyroid tissue and its phantom. In conclusion, this study proves the feasibility and reliability of epoxy resin application in the production of two-piece thyroid-neck phantom. This phantom can be applied in the calibration of gamma camera systems, dosimetry and gamma spectrometry in the nuclear medicine field.

Authors and Affiliations

M. Karimi, H. Mostaghimi, S. F. Shams, A. R. Mehdizadeh

Keywords

Related Articles

Diagnosis of OCD Patients Using Drawing Features of Bender Gestalt Shapes

Background: Since psychological tests such as questionnaire or drawing tests are almost qualitative, their results carry a degree of uncertainty and sometimes subjectivity. The deficiency of all drawing test is that the...

Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams. Materials and Methods: Monte Carlo simulat...

Parametrization of Pedestrian Injuries and its Utilisation in Proving Traffic Accidents Course Using Injury Signatures and Contact Signatures

Background: The paper points out the present limited possibility of using the verbal description of injuries for the needs of experts from the field of road transportation as relevant criminalistics traces, as well as th...

Optimization of Brain Tumor MR Image Classification Accuracy Using Optimal Threshold, PCA and Training ANFIS with Different Repetitions

Background: One of the leading causes of death is brain tumors. Accurate tumor classification leads to appropriate decision making and providing the most efficient treatment to the patients. This study aims to optimize b...

Closed- and Open-loop Deep Brain Stimulation: Methods, Challenges, Current and Future Aspects

Deep brain stimulation (DBS) is known as the most effective technique in the treatment of neurodegenerative diseases, especially Parkinson disease (PD) and epilepsy. Relative healing and effective control of disease symp...

Download PDF file
  • EP ID EP453805
  • DOI -
  • Views 96
  • Downloads 0

How To Cite

M. Karimi, H. Mostaghimi, S. F. Shams, A. R. Mehdizadeh (2018). Design and Production of Two-piece Thyroid-neck Phantom by the Concurrent Use of Epoxy Resin and Poly(methyl methacrylate) Soft Tissue Equivalent Materials. Journal of Biomedical Physics and Engineering, 8(2), 217-222. https://europub.co.uk/articles/-A-453805