Cheek Plumper: Magnet Retained Approach to Enhance Esthetics for Sunken Cheeks

Journal Title: Journal of Advanced Medical and Dental Sciences Research - Year 2018, Vol 6, Issue 7

Abstract

Changes in the skin are an inevitable part of aging. It’s quite common for the cheeks to deflate as the cheek pads lose fat retention and the skin loses elasticity. As the skin begins to sag, the area around the mouth can appear worn and aged. These negative side effects of age are only exacerbated by poor diet and a lack of exercise. Certain health conditions can also make the cheeks appear hollow. As esthetics is one of the objectives in complete denture prosthesis. This clinical report describes technique to improve support for sunken cheeks using magnet retained detachable acrylic cheek plumpers. The new generation of magnets with improved technology provides sufficient denture retention for clinical application. However, further follow-up may be necessary to ascertain the long-term usefulness of the magnet-retained prosthesis, because of corrosion and further loss of magnetism.

Authors and Affiliations

Vidya Hittalamani, Premaraj Jadhav, Milind Limaye, Pradeep Taide

Keywords

Related Articles

STUDY OF SERUM CYSTATIN C TO DETECT EARLY ACUTE KIDNEY INJURY IN ADDITION TO ROUTINE RENAL FUNCTION TESTS IN ACUTELY ILL PATIENTS

Early diagnosis of Acute Kidney Injury in Emergency department is a challenging task. Current diagnostic criteria for AKI poorly recognize early renal dysfunction & may cause delayed diagnosis. We evaluated the use of se...

Efficacy and safety of Olopatadine versus Azelastine in allergic conjunctivitis at a Government Medical College, Betiah, Bihar- A prospective study

Background: Allergic eye diseases influences around one-fifth of the total populace. Olopatadine hydrochloride and Azelastine hydrochloride are double acting selective H1 receptor antagonist with mast-cell stabilizing pr...

Whether adequate attention given to confounding factors affecting tooth movement in canine retraction studies? - A literature review with systematic criteria

Background: The commonly used models to evaluate orthodontic tooth movement(OTM)in humans are canine retraction, lower anterior de-crowding, premolar buccal/apical movement, incisor apical movement, en-mass retraction, m...

DISINFECTION OF EXTRACTED HUMAN TEETH: A COMPARATIVE STUDY

Background: Extracted teeth are used commonly by dental students as well as researchers to improve their technical skills for future dental practice as well as to conduct various studies. Extracted teeth are a potentia...

Malignant Transformation of Oral Leukoplakia: Study of 50 Patients

Background: Oral leukoplakia (OL) is the best-known potentially malignant disorder. The objective of this study is to estimate the rate of malignant transformation in a patients with leukoplakia for more than 5 years and...

Download PDF file
  • EP ID EP548087
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

Vidya Hittalamani, Premaraj Jadhav, Milind Limaye, Pradeep Taide (2018). Cheek Plumper: Magnet Retained Approach to Enhance Esthetics for Sunken Cheeks. Journal of Advanced Medical and Dental Sciences Research, 6(7), 46-50. https://europub.co.uk/articles/-A-548087