Comparative Evaluation of Fracture Resistance in Custom Made And Prefabricated Posts.

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2017, Vol 16, Issue 12

Abstract

Introduction: Badly mutilated teeth presents a challenge for the clinician to determine whether tooth is to be managed endodontically by performing root canal treatment or surgically by undergoing extraction. Pre fabricated posts poses the advantage of saving precious chair time of dentist where as erodes excessive dentine leading to weakening of sound tooth structure. Custom made posts are technique sensitive; can be prepared directly in mouth (direct technique) or in the model obtained from the patient (Indirect technique). The purpose of the present study is to study the fracture resistance of prefabricated and custom posts. Materials & Method: 10 prefabricated posts and 10 custom made posts were used in the study. For prefabricated posts, posts of size 2 (11 cm in length and 2.5 mm in width) were used in the study. Impression of prefabricated post was made in addition silicone putty to fabricate the index and casting was carried out using Cr-Co-Ni alloy. All the samples were placed in distilled water for 2 days and loaded for thermocycling of 6000 cycles with 1 minute interval. The head of the universal testing machine was placed at cross sectional speed of 5mm/minute until posts tested were fractured. All the data were recorded and data was analyzed statistically. Results: In intergroup comparison between the group 1 and group 2, Group 2 recorded mean value of 326.19 ± 20.64 kg where as group 1 recorded mean value of 222.8 ± 56.58 kg. Results were interpreted and one way analysis of variance was carried out. Conclusion: Custom made posts was found to be more fracture resistant than their counterpart prefabricated posts

Authors and Affiliations

Rajat R khajuria, Mukesh kumar, Dr. Romil Safaya, Dr. Nauseen Hajira, Dr Rishav singh

Keywords

Related Articles

Haematological and Clinical Assessment of Steady State Homozygous Hb Sand Homozygous Hb A

Introduction:The abnormalities in patients with sickle cell anaemia (HbSS) result in multi- organ and systemic complications and clinical manifestations. The study aims at assessing and determining the correlates of the...

Prevalence of Urinary Tract Infection In General Medicine Ward In A Tertiary Care Hospital And Its Bacteriological Profile

Urinary tract infections(UTI) is the most common bacterial infection prevalent in both males and females and contribute to second most common nosocomial infection raising the hospital stay, morbidity and various complica...

Study of Cardiovascular Autonomic Dysfunction in Type 2 Diabetes Mellitus

Background: Type 2 Diabetes mellitus is the most common metabolic and endocrine disorder that is characterized by hyperglycemia (high blood sugar) in the context of insulin resistance and shortage of insulin. Obesity and...

Retrospective Study on the Decision to Delivery Interval

The decision-to-delivery interval (DDI) is defined as the interval in minutes from the date and time of decision to carry out Caesarean section to the date and time of delivery of the baby. It is not synonymous with deci...

Impact of Kisspeptin on Prematur Puberty in Obese Girls

Kisspeptin is a peptide hormone that appears to play a major role in the regulation of GnRH secretion,the researchaims to study the relationship between obesity and premature puberty touched by influence of kisspeptin co...

Download PDF file
  • EP ID EP251736
  • DOI 10.9790/0853-1612131114
  • Views 42
  • Downloads 0

How To Cite

Rajat R khajuria, Mukesh kumar, Dr. Romil Safaya, Dr. Nauseen Hajira, Dr Rishav singh (2017). Comparative Evaluation of Fracture Resistance in Custom Made And Prefabricated Posts.. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 16(12), 11-14. https://europub.co.uk/articles/-A-251736