Comparison of Power Quality Improvement by D-STATCOM and Distributed Generation in Distribution System

Abstract

In t his paper proposes operation and control of converter b a s e d single phase distributed generators (DG) in a utility connected grid. A common utility practice is to distribute the household single-phase loads evenly between the three phases. The voltage unbalance between the phases remains within a reasonable limit. However the voltage unbalance can be severe if single-phase rooftop mounted PVs are distributed randomly between the households. Moreover, there can also be single phase non-linear loads present in the system. The cumulative effect of all these will cause power quality problems at utility side. The problem can be macabre if three-phase active loads (e.g., induction motors) are connected to utility feeder. To counteract this problem, first scheme a distribution static compensator (DSTATCOM) is connected at the utility bus to improve the power quality. The DSTATCOM only supplies reactive power and no real power. In the second scheme, a larger three-phase converter controlled DG is placed that not only supplies the reactive power but also provides active power. The efficacies of the controllers have been validated through simulation for various operating conditions using MATLAB.

Authors and Affiliations

G. Saritha, Dr. Chandrashekhar Reddy. S,

Keywords

Related Articles

Energy Efficient Wireless Sensor Network Using Cooperative Communication

A network like sensor networks have energy constrained devices. The energy consumed by the nodes need to be less which prevents the earlier death of the sensor nodes due to drained energy level. Several techniques, meth...

Speed Control of Brushless DC Motor Using Proportional Integral Controller

Ease control and high power density are the two main reasons for using brushless DC motor in wide range of industrial applications. In general the brushless DC motors are controlled using power Semiconductor bridge. So...

A Modern Design of Torque Ripples Reduction in BLDC Drive for Electric Vehicle Application

BLDC motors are one of the motor type’s fast gaining the interest of the researchers. This motor attracts to a great extent concern due to its better speed, high dynamic response, high efficiency, long operating life, n...

Data Handling using Oracle Data Guard by the Transfer of Log Sequence.

Oracle Data Guard ensures high availability, data protection, and disaster recovery for enterprise data. Data Guard provides a comprehensive set of services that create, maintain, manage, and monitor one or more standby...

Design and Implementation of Intelligent Controller for a Continuous Stirred Tank Reactor System

All the industrial process applications require the solutions of a specific chemical strength of the chemicals or fluids considered for analysis. Continuous Stirred Tank Reactor (CSTR) is one of the common used reactors...

Download PDF file
  • EP ID EP21496
  • DOI -
  • Views 199
  • Downloads 3

How To Cite

G. Saritha, Dr. Chandrashekhar Reddy. S, (2015). Comparison of Power Quality Improvement by D-STATCOM and Distributed Generation in Distribution System. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(12), -. https://europub.co.uk/articles/-A-21496