Comparison of stress distribution around implants with two different attachments in overdenture supported by four maxillary implants (FEA method)

Journal Title: Scholars Journal of Dental Sciences - Year 2017, Vol 4, Issue 7

Abstract

As a general rule, the purpose of treatment planning should be minimization and evenly distribution of mechanical stress in the adjacent implant and bone system. Various experimental studies have examined the distribution of stress in the implant supporting bones, thus avoiding the dangers involved. But there is still controversy about biomechanical effects and stress distribution in different attachment designs.The purpose of this study was to compare the distribution of stress around the implant with two different attachments in overdenture based on four maxillary implants using finite element analysis method (FEA). In this experimental study, using the FEA method, a 2D model of maxilla, implant, attachment components and overdenture was first prepared and then, using the ANSYS finite element software, the components of the model were superimposed on each other so that it can act as a component integrated with different materials. These implants were attached to the overdenture using three ball, and locator attachment designs. The 100N force used in this study. Among the two different designs examined, the highest stress was observed in the vertical force (22.87 MPa) imposed on the implant in the right second premolar on the right overdenture supported by the locator implant. In the second place, the highest stress was observed on the Ball-retained overdenture in the right side force, imposed on the implant in the right second premolar corresponding to 12.88 MPa. The least stress among these three designs was observed in the ball-retained overdenture design. Ball-retained overdenture with the lowest stress caused by the 100 N force is the most appropriate design in the present study. Keywords:Finite element method; stress test; ball attachment; locator attachment; overdenture

Authors and Affiliations

Dr. Asadallah Ahmadzadeh, Dr. Ahmad Teimouri

Keywords

Related Articles

Evaluation of Myofibroblasts by Expression of Alpha Smooth Muscle Actin (Α-SMA) in Oral Sub mucous Fibrosis

Abstract: Oral Sub mucous Fibrosis (OSF) is a chronic inflammatory oral potentially malignant disorder caused due to recant chewing characterized by excess collagen deposition in the submucosa leading to restricted mouth...

Denture Induced Gingival Hyperplasia-A Case Report

Abstract: Gingival overgrowth is a common clinical finding and most of them represent a reactive hyperplasia caused by various etiological factors, plaque being a major etiology. Gingival enlargement can be focal or diff...

Inferior Alveolar Nerve Paresthesia Related to Apical Periodontitis of Mandibular Third Molar

Abstract: Paresthesia of the inferior alveolar nerve (IAN) as the result of preapical inflammation or endodontic treatment is a rare but serious occurrence. The following case report describes the diagnosis and managemen...

Awareness towards Orthodontic Treatment in Central Indian School Children

Abstract: The aim of present study is to assess the awareness towards orthodontic treatment among school children’s of Bilaspur Chhattisgarh, India. The survey was carried out in selected schools in all the district head...

Comparative Evaluation of Compressive Strength of Ketac Molar, Zirconomer, and Zirconomer Improved

The ability of a dental restorative material to withstand occlusal forces is one of the major properties to be taken into consideration in restorative practice. Various materials are commercially available, exhibiting ha...

Download PDF file
  • EP ID EP379515
  • DOI -
  • Views 76
  • Downloads 0

How To Cite

Dr. Asadallah Ahmadzadeh, Dr. Ahmad Teimouri (2017). Comparison of stress distribution around implants with two different attachments in overdenture supported by four maxillary implants (FEA method). Scholars Journal of Dental Sciences, 4(7), 313-322. https://europub.co.uk/articles/-A-379515