Comparison of stress distribution around implants with two different attachments in overdenture supported by four maxillary implants (FEA method)
Journal Title: Scholars Journal of Dental Sciences - Year 2017, Vol 4, Issue 7
Abstract
As a general rule, the purpose of treatment planning should be minimization and evenly distribution of mechanical stress in the adjacent implant and bone system. Various experimental studies have examined the distribution of stress in the implant supporting bones, thus avoiding the dangers involved. But there is still controversy about biomechanical effects and stress distribution in different attachment designs.The purpose of this study was to compare the distribution of stress around the implant with two different attachments in overdenture based on four maxillary implants using finite element analysis method (FEA). In this experimental study, using the FEA method, a 2D model of maxilla, implant, attachment components and overdenture was first prepared and then, using the ANSYS finite element software, the components of the model were superimposed on each other so that it can act as a component integrated with different materials. These implants were attached to the overdenture using three ball, and locator attachment designs. The 100N force used in this study. Among the two different designs examined, the highest stress was observed in the vertical force (22.87 MPa) imposed on the implant in the right second premolar on the right overdenture supported by the locator implant. In the second place, the highest stress was observed on the Ball-retained overdenture in the right side force, imposed on the implant in the right second premolar corresponding to 12.88 MPa. The least stress among these three designs was observed in the ball-retained overdenture design. Ball-retained overdenture with the lowest stress caused by the 100 N force is the most appropriate design in the present study. Keywords:Finite element method; stress test; ball attachment; locator attachment; overdenture
Authors and Affiliations
Dr. Asadallah Ahmadzadeh, Dr. Ahmad Teimouri
Gender Predictability of Permanent Maxillary First Molar – A South Indian Study
Abstract: The study investigates the gender predictability of permanent maxillary first molar teeth. Mesio distal width of 30 permanent maxillary first molar teeth from casts of 15 male and 15 female patients between the...
Gorlin Gortz Syndrome: A Rare Case Report
Abstract: Gorlin-Goltz syndrome which is also known as Bifid rib syndrome comprises of multiple organ system. One of the most common features includes the multiple odontogenic keratocysts in maxilla or mandib...
Impact of change in Loop designs and it’s wire materials in Orthodontics: A Review
Abstract: Extraction space closure in one of the important steps in orthodontic treatment. Number of loop configuration available in the literature. These loop designs that have been described have specific applications...
Comparison between Conventional Radiography (IOPA) and Digital Radiography Using Bitewing Technique in Detecting the Depth of Alveolar Bone Loss
Abstract: The objective of present study is to assess the depth of alveolar bone loss by using Conventional radiography (IOPA) and Digital radiography (RVG) technique in periodontitis as it affects the connective tissue...
Three rooted maxillary first premolar- a case report
Abstract: Endodontic literature has described the standard anatomy of maxillary first premolar to have two roots and two canals. At the same time, there are many cases reports documenting numerous aberrations in its root...