Considerations about the Development of Protective Devices on the Increase Safety in Exploitation of the Electric Power Transformers
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2013, Vol 37, Issue 37
Abstract
Installations and devices of the protection, mounted on transformer, are: oil conservator, gas relays, thermo-siphon filters, air filters, safety valves and thermal image (thermo-copy). Here are some contributions to the development of devices to increase safety in exploitation of power transformers such as gas protection on-line and relay protection for on-load-tap-changers. The constructive principles of gas Buchholz relay (patented in 1921) remained generally unchanged, as with all the past nearly 100 years. In the exploitation of electrical power transformers have been noticed, on the basis of statistics prepared in the USA since 1947, a number of inconveniences. In first place is erroneous operation of lifting-contacts with mercury, in terms of vibrations, as for example disconnection of power transformers through gas protection, in high voltage stations of Romania, at the 1977 earthquake. As a result, in practice showed various models: gas relays with magnetic contacts, gas relays with cups and resort, gas relays with bellows, electronic gas relays and others. These have a correspondent to the versions equipped with a single float that are used as protection for on-load-tap-changers. For this reason, we have studied and protection of on-load-tapchanger, that command disconnecting breakers of the transformer, when current speed of oil through pipe, from tank of the on-load-tap-changer to the oil conservator, exceeds a threshold value. Thus, the capacitor C2 (from the scheme of the gas protection on-line for power transformers), patented individually under the name Flag to flow velocity, meets all conditions in order to provide as protection for the on-loadtap- changer. Protections gas integration in SCADA (Supervisory Control and Data acquisitions) is the last issue addressed before final conclusions.
Authors and Affiliations
Tiberiu-Octavian Cujba
Design Optimization of an Asynchronous Motor Used in Light Railway Traction
The appropriateness of this work is provided by highlighting some aspects insufficiently treated in the areas of designing and dimensioning of asynchronous traction motors associated with light traction static converters...
Analyzing Signals from a Primary Winding of a Locomotive Transformer with Three Types of Wavelet-Based Transforms
The paper is concerned with the analysis of in-stantaneous values and evaluation of certain power quality indices corresponding to phase currents and voltages ac-quired from the primary winding of a locomotive trans-form...
INSULATION RESISTANCE TESTING OF THE MEDIUM VOLTAGE SWITCHES
This paper refers, in general, to the problem of off-line diagnosis of automated switches, and in particular it refers to the testing procedures regarding the insulation resistance. The factors that have a negative influ...
Energetic Analysis of the Drying Process of Cur-rent Transformers from 110 kV Ciungetu Power Station
Currently, at company Hidroserv Râmnicu Vâlcea, the drying of current transformers used in power transformer stations is done by a combination between induction and conduction heating at the frequency of 50 Hz. Obviously...
Modeling and Simulation of the Coal Flow Control System for the Longwall Scraper Conveyor
In this paper, the modeling and simulation of a coal flow control system for the longwall scraper conveyor is presented. The coal flow on the scraper conveyor, it is controlled by the following variables: the coal flow,...