Design Optimization of an Asynchronous Motor Used in Light Railway Traction
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2017, Vol 41, Issue 41
Abstract
The appropriateness of this work is provided by highlighting some aspects insufficiently treated in the areas of designing and dimensioning of asynchronous traction motors associated with light traction static converters. The traction system is aimed for the light railway vehicles. Through the usage of asynchronous motors supplied by independent converters, the performances concerning the traction and the electric braking system are improved, while the maintenance expenses are reduced. The newly designed motor is aimed for the traction system of a locomotive driv-ing a multiple unit train, while the parameters necessary for the analysis of the regenerative braking system are also ac-counted for. An algorithm for the optimal design of the asynchronous motor is developed, considering the main parameters as the electric and magnetic quantities, the manufacturing and operating costs. The motor dimensions are computed starting from the values of the electromagnet-ic quantities resulted in the optimization process. The opti-mization algorithm is realized in Mathcad, any parameter modification leading to a new motor model. The main objec-tive of the paper is to optimally design the asynchronous traction motor directly rotating the drive wheel of the elec-tric train. The motor design takes into account the statio-nary rated regime, with the speed adjustment within wide limits, frequent starts and stops.
Authors and Affiliations
Raluca-Cristina Presură, Petre-Marian Nicolae, Ion Vlad
THERMAL AGEING OF OIL IMPREGNATED PAPER FOR POWER TRANSFORMERS INSULATION SYSTEMS
The assessment of conditions and life time reserves of power transformers is generally done based on the analysis of characteristics of main components of insulation systems (oil and paper). During operation, the insula...
DESIGN AND PERFORMANCES OF COUPLING PASSIVE FILTERS IN THREE-PHASE SHUNT ACTIVE POWER FILTERS
The passive interface filter represents the link between the power grid and the shunt active filter. The interface filter is used both to obtain a good dynamic of the compensating current and to limit the high frequency...
The influence of ambient temperature on the potentiality of integrated systems for wind energy conversion into electricity
The main purpose of this paper is to view the influence of ambient temperature on the magnetic vector potential of a particular data structure, and thus the magnetic field distribution within the structure. The secondary...
Control circuit of an Electronically Controlled Capacitor for the Optimization of the Single Phase Induction Motor
The control circuit of an Electronically Controlled Capacitor (ECC) for the optimization of the Single Phase Induction Motor (SPIM) with auxiliary winding is presented. The control circuit is based on a fixed value...
RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz
Electromagnetic environmental conditions checking and provision regarding long and short time human personal and occupational exposure is regulated by international standards. Generally, the human being is exposed mainly...