Cuffed Endotracheal Tube Size and Leakage in Pediatric Tracheal Models

Abstract

Object: Cuffed endotracheal tubes are increasingly used in pediatric patients in the hope that they can reduce air leakage and tube size mismatch by just inflating the cuff. Authors compared influence of various tube sizes and different levels of cuff pressures to air leakage around the cuff, in artificial tracheal models. Methods: Six PVC cylinders of different internal diameters (ID: 8.15, 8.50, 9.70, 12.05, 14.50, and 20.00 mm) were prepared. An artificial lung connected with cylinder was ventilated with an anesthesia machine. Cuffed endotracheal tubes of different sizes (ID 3.0~8.0) were located in the cylinders and the cuff was inflated with various pressures (15, 20, 25, 30 and 35 cm H2O). Expiratory tidal volume was measured with more than 25% loss of baseline expiratory tidal volume was considered significant air leakage. Results: Tube sizes same as, or larger than ID 5.0 didn’t show significant air leakage for any trachea model, only if the inflated cuff size is larger than the cylinder ID, except ID 5.5 tube at cuff pressure 15 cm H2O and 20 cm H2O, in 12.05 mm cylinder. Tubes sizes same as or smaller than ID 4.5, which have short cuff lengths and sizes than tubes larger than, or same as ID 5.0, leaked significantly at any tracheal models, except ID 4.5 tube at cuff pressure 35 cm H2O, in 8.50 mm cylinder. Conclusion: In PVC pediatric tracheal models, tubes same as, or smaller than ID 4.5 are inferior to tubes same as, or larger than ID 5.0 in preventing air leakage, and may need a higher cuff pressure to reduce air leakage. Further clinical studies could be designed based on our results.

Authors and Affiliations

Joo Choe Won, Hyun Kim Jun, Woo Kim Kyung, Lee Sang-il, Yeon Kim Ji, Kim Kyung-Tae, Su Park Jang, Won Kim Jung

Keywords

Related Articles

Delayed Intractable Postextubation Laryngeal Edema after General Anesthesia

We report a case of delayed intractable postextubation laryngeal edema after extubation in 78-year-old female patient who underwent uneventful operation. The patient had underwent tracheostomy 30 years ago. After 14 hour...

Degree of Motor Block Measured by Bromage Scale is not Correlated with Muscle Relaxation

Background and Aim Achieving adequate motor and sensory blockage in spinal anesthesia allows the comfortable performance of surgical interventions. However, in certain operations on the lower extremities, surgeons report...

Reversal with Sugammadex in the Absence of Neuromuscular Monitoring

Sugammadex provides rapid and reliable recovery of neuromuscular (NM) function from rocuronium or vecuronium-induced NMblockade than neostigmine. The dose of sugammadex, ranges from 2 to 16 mg/kg, is adequately matched w...

Predictors of Outcome in COPD Patients with Hypercapnic Respiratory Failure Requiring NIV

Background and Objectives: Delay in identifying patients in whom NIV will be unsuccessful may postpone endotracheal intubation, increasing morbidity and mortality. Aim of this study was to determine factors associated wi...

IABP: The Show Goes on but All that Glitters is not Gold

Despite remarkable improvements in early diagnosis and treatment of acute myocardial infarction (AMI), cardiogenic shock is still the most common cause of in hospital mortality and morbidity associated with AMI, which oc...

Download PDF file
  • EP ID EP618269
  • DOI -
  • Views 194
  • Downloads 0

How To Cite

Joo Choe Won, Hyun Kim Jun, Woo Kim Kyung, Lee Sang-il, Yeon Kim Ji, Kim Kyung-Tae, Su Park Jang, Won Kim Jung (2014). Cuffed Endotracheal Tube Size and Leakage in Pediatric Tracheal Models. Enliven: Journal of Anesthesiology and Critical Care Medicine, 1(3), 22-28. https://europub.co.uk/articles/-A-618269