Damages to stent stabilized left ventricular pacemaker electrodes during simulated lead extraction 

Journal Title: Frattura ed Integrità Strutturale - Year 2011, Vol 5, Issue 16

Abstract

During biventricular pacemaker implantation stents can be applied for coronary sinus lead stabilization to prevent lead dislocations. A lot of issues have been raised in connection with the use of the stent. In some cases the implanted left ventricular lead must be explanted. It is crucial to avoid any injury to the heart when the electrode is removed. Another very important question concerns the type of injuries the electrode may cause during the removal process. An extraction model has been prepared using a special curve and a polymer tube. After the pacemaker leads were extracted, various microscopic examinations were executed. The findings may to make such intervention methods more successful, helping to better stabilize the electrode and to keep injuries during interventions to a minimum. 

Authors and Affiliations

Romola Laczkò, Tibor Balzs, Eszter Bognàr, Jànos Ginsztler

Keywords

Related Articles

 A study of white etching crack formation by compression-torsion experiments

  In this study, an attempt was made to recreate the bearing damage phenomenon “White Etching Cracks” with a simplified testing setup. Rolling contact fatigue conditions were simulated with in-phase and out-ofphase...

 Static and dynamic experimental study of strengthened reinforced short concrete corbel by using carbon fabrics, crack path in shear zone

 The paper presents an experimental analysis of tracking the path of the cracks and crack growth in strengthened or repair reinforced concrete short corbels bonded by carbon fiber fabrics under static and dyna...

 Sulla storia degli studi di frattura in Italia

La storia degli studi sulla frattura è inestricabilmente connessa con il progresso della tecnologia. All'inizio pochissimo fu scritto. Dobbiamo riconoscere a Leonardo e Galileo il merito di essere stati fra i primi a scr...

 Study of the influence between the strength of antibending of working rolls on the widening during hot rolling of thin sheet metal

 Based on the variation principle of Jourdan was developed a mathematical model of the process of widening freely in hot rolling of thin sheet metal. The principle applies to rigid-plastic materials and for the ci...

 The effect of ply folds as manufacturing defect on the fatigue life of CFRP materials

  Manufacturing defects are inherent to any manufacturing process. However, in composite materials they might be unavoidable, e.g. ply waviness or even folds of plies are present in complex shaped parts during high...

Download PDF file
  • EP ID EP113836
  • DOI 10.3221/IGF-ESIS.16.03
  • Views 70
  • Downloads 0

How To Cite

Romola Laczkò, Tibor Balzs, Eszter Bognàr, Jànos Ginsztler (2011). Damages to stent stabilized left ventricular pacemaker electrodes during simulated lead extraction . Frattura ed Integrità Strutturale, 5(16), 28-33. https://europub.co.uk/articles/-A-113836