Abstract
The main power quality eccentricities are occurred by Ferranti effect, short-circuits, voltage sparks, voltage swells harmonic distortions, voltage sags and transients occur by switching of load. The fundamental sinusoidal waveform of current will change when we are using a non-linear load in a power system. Power quality are modify reactive power problem such as power factor lagging due to inductive load or voltage multiplication using Ferranti effect by Thyristor Switched Reactance (TSR) and Thyristor Controlled Reactor (TCR) are two of shunt FACTS(flexible AC transmission system) devices have been used as an alternative to fixed shunt capacitors and fixed reactors in power systems. Application Fuzzy logic on 8 bit microcontroller to sense power quality and employ corrective action and system is designed using fuzzy logic controller and MAT Lab coding.
Authors and Affiliations
Mr. Rajaji Shah,
Design and Development of a Fuzzy Logic Implementation of a Microcontroller Based FACTS Employing Thyristor Controlled Reactor/ Thyristor Switched Reactance for Power Quality Management
The main power quality eccentricities are occurred by Ferranti effect, short-circuits, voltage sparks, voltage swells harmonic distortions, voltage sags and transients occur by switching of load. The fundamental sinusoid...
Voltage Stability by Injecting Reactive Power using STATCOM for Wind Turbine Squirrel-Cage Induction Generator System during Fault
Reactive power limit of the system affects it’s Voltage stability. The wind driven self excited induction generator during faults and heavy loading condition, lacks in supplying reactive power to the system. FACTs device...
Comparison of GA and PS Optimization Mechanisms for Optimizing 100MW Delta IV Ughelli Gas Turbine Power Plant Operating Parameters
A comparative analysis for improving the efficiency of 100MW Delta IV Ughelli gas turbine power plant is performed. The study used non-dominated sorting genetic and pattern search algorithms to minimize the objective fun...
Uses and Comparison of Multi Input Converter Topology with Power Control
In this article a new topology is introduces which shows multiple energy sources input to a common load. But as we know about that all different type of energy sources have different voltage and current characteristic an...
Reactive Power Compensation and Power Injection through Distributed Generation Sources
Renewable energy resources are connected in distribution systems to achieving benefits. A control strategy to consummate favor from these grid-interfacing inverters when installed in 3-phase 4-wire distribution systems i...