Effect Assessment of TCSC on Algerian Transmission Line Protected by IDMT Directional Overcurrent Relay
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2014, Vol 38, Issue 38
Abstract
The paper presents the effect of apparent reactance and injected voltage by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) on transmission line high voltage protected by an Inverse Definite Minimum Time (IDMT) Directional Overcurrent Relay (DOCR) based International Electrotechnical Commission (IEC) standard characteristic curve. The DOCR is used to protect a 400kV transmission line of the Algerian transmission power systems which belong to the Algerian Company of Electrical. The effects of TCSC on protected transmission line parameters (reactance and resistance) as well as fault current and operation time of the DOCR in the presence of phase to earth fault with fault resistance for three cases study is investigated.
Authors and Affiliations
Mohamed ZELLAGUI, Rabah BENABID BENABID, Abdelaziz CHAGHI
DEVELOPMENT, MANUFACTURE AND TESTING OF HORIZONTAL AXIS WIND MICROTURBINES WITH POWER OF 10 KW
Under the circumstances of the total energetic recourses deficit in the Republic of Moldova appears the problem of non-traditional sources utilization recovered by energy. Important sources of renewable energy are the wi...
Inductive Power Charging for Electric Vehicles in Misalignment Conditions
This research work deals with the challenges and issues facing the misalignment contactless inductive power charging of electric vehicles (EVs). The focus is on analysis and design of the inductive power transfer (IPT) f...
EXPERT SYSTEM FOR POWER RECTIFIERS DIAGNOSIS
In designing of the static power converters, the experience of an expert is absolutely necessary in order to obtain a competitive solution. The evolution of the CAD methods has brought in the last time expert systems w...
Indirect Current Control Algorithm Implementation and Validation, for Active Filtering Using Constant Switching Frequency Hysteresis Controllers
The aim of this paper is the implementation and the experimental validation of a constant switching frequency hysteresis current controller as a part of an active filtering system control algorithm, based on the indirect...
RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz
Electromagnetic environmental conditions checking and provision regarding long and short time human personal and occupational exposure is regulated by international standards. Generally, the human being is exposed mainly...