Effective Electromechanical Coupling for the Partially Electroded Ceramic Resonators of Different Geometries

Abstract

Effective electromechanical coupling factor (ECF) was studied on bar, disc and ring ceramic resonators partially covered by electrodes. ECFs were calculated theoretically and verified experimentally. Bar resonators (k31-mode) show maximum value of ECF keff = 0.26 at the electrode aspect ratio equal to 0.75 with calculated values fitting the experimental data for all aspect ratios. Calculations for bar resonators with embedded electrodes (k33-mode) show similar behavior like for k31-mode, but at higher ECFs. Maximum value of ECF for such a mode reaches keff = 0.67 for the electrode aspect ratio of 0.75. Partially electroded disc resonators (kpmode) are well described analytically by one-dimensional model only for the electrode aspect ratios up to 0.5. Maximum value keff = 0.58 for disc resonators was measured at the electrode aspect ratio equal to 0.80. Partially electroded ring resonators (kp-mode) show the same trend as discs without saturation of ECF values. Maximum ECF keff = 0.34 was measured for ring resonators with full electrode. The presented analytical formulae may serve as a guide for the optimum electrode pattern design for the partially electroded resonators.

Authors and Affiliations

ERHART JIŘÍ, Sebastian TUTU

Keywords

Related Articles

The Study of Metal-Old Wood Interactions Under the Influence of Pedological Factors

In the manufacture of wood objects, for binding and strengthening were used nails, cramps and other metallic elements, which in the archaeological site suffered degradation and deterioration processes, specific to metal-...

Corrosion Behaviour of Tombac Used in Cult Objects Manufacturing

Corrosion of metals and metallic alloys is due to their thermodynamic instability in relation to their oxidation form. Corrosion tests performed in this work simulate the exposure conditions in different environments of...

Experimental and Theoretical Investigations on Mode I Crack Propagation in Notches under Cyclic Loading

Research works regarding crack opening stresses covering various types of Mode I cracks initiated and growing in notches under cyclic loading are shown. A large number of parameters influence the crack opening behavior,...

The Sonic Waste Water Treatment

Sonic technology means the technology where the sonic devices are used and where the intensification of the heat and mass transfer is obtained owing to the pressure or flow capacity oscillations, introduced in the techno...

Detailed Microcontroller Architecture Based on a Hardware Scheduler Engine and Independent Pipeline Registers

In the world of real time operating systems, task switching, communication between threads and synchronization are implemented in software. Some of the mechanisms used may introduce big latencies in task recurrence, task...

Download PDF file
  • EP ID EP581358
  • DOI -
  • Views 100
  • Downloads 0

How To Cite

ERHART JIŘÍ, Sebastian TUTU (2015). Effective Electromechanical Coupling for the Partially Electroded Ceramic Resonators of Different Geometries. Analele Universitatii "Dunarea de Jos" din Galati. Fascicula IX, Metalurgie si Stiinta Materialelor, 38(2), 7-16. https://europub.co.uk/articles/-A-581358