Energy Analysis of Selected Air Distribution System of Heating, Ventilation and Air Conditioning System: A Case Study of a Pharmaceutical Company

Abstract

The higher energy consumption causes environmental degradation along with depletion of conventional energy resources. The share of energy consumption in buildings is increasing with urbanization and that ultimately requires effective measures for energy conservation. In buildings, HVAC (Heating Ventilation and Air Conditioning) systems require huge amount of energy. This paper estimates the effects of compression of duct insulation of an HVAC system onthe auxiliary power consumption and temperature of supplied air. A mathematical model is developed in EES (Engineering Equation Solver) to ascertain these effects. The simulation results show that the cooling loss due to the insulation compression is about 14%. By increasing the insulation thickness from 10-40mm at selected points, the heat gain is estimated to decrease from 4.29-2.46kW. In addition to that effects of compression of thermal insulation on GHG (Greenhouse Gas) emission are investigated to reduce from 4.2-2.3kg/ kW. Subsequently, the AC (Auxiliary Consumption) and temperature of the supplied air decrease by 5% and 0.4oC, respectively

Authors and Affiliations

Dileep Kumar, Rizwan Ahmed Memon, Abdul Ghafoor Memon

Keywords

Related Articles

Projected Rainfall Variability Based on PRECIS Regional Model

The present study indicates the potential projected variation of decadal mean rainfall over Kohistan region of Sindh Province, Pakistan. Precipitation variability is a crucial climatic factor that affects human health an...

LTE and GPS based Deca Band Printed Antenna for Cellular Mobile Handset Communication Applications

This paper presents novel mobile phone antenna for radiations simultaneously in ten frequency bands for applications of LTE (Long-Term Evolution), GPS (Global Positioning System), GSM (Global System for Mobile Communicat...

Assessment of Air Pollution and its Effects on Health of Workers of Steel Re-Rolling Mills in Hyderabad

The SRRMs (Steel Re-Rolling Mills) are being releasing air pollutants in the environment. In order to evaluate their effect on the health of the workers, health and safety issues were analyzed by first measuring the conc...

Effect of Temperature and Time on Nickel Aluminide Coating Deposition

The βNiAl coating was deposited onto Nickel based CMSX-4 superalloy by in-situ CVD (Chemical Vapor Deposition) method. Main focus of this contribution was to study the influence of aluminizing time and temperature on the...

Identifying the Wasted Spaces within Hospital Buildings in Pakistan

The built environment of hospital buildings are generally not accepted to be pleasant. In the design of healthcare facility, it is quite important that its design, spatial arrangement and areal distribution must respond...

Download PDF file
  • EP ID EP207725
  • DOI 10.22581/muet1982.1703.29
  • Views 90
  • Downloads 0

How To Cite

Dileep Kumar, Rizwan Ahmed Memon, Abdul Ghafoor Memon (2017). Energy Analysis of Selected Air Distribution System of Heating, Ventilation and Air Conditioning System: A Case Study of a Pharmaceutical Company. Mehran University Research Journal of Engineering and Technology, 36(3), 745-756. https://europub.co.uk/articles/-A-207725