Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study
Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 1
Abstract
Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations. Objective: The present study has been undertaken to find out inter- and intralung density variations and its dosimetric impact on lung cancer radiotherapy using Monte Carlo code FLUKA and PBC algorithms. Material and Methods: Density of 100 lungs was recorded from their CT images along with age. Then, after PDD calculated by FLUKA MC Code and PBC algorithm for virtual phantom having density 0.2 gm/cm3 and 0.4 gm/cm3 (density range obtained from CT images of 100 lungs) using Co-60 10 x10 cm2 beams were compared. Results: Average left and right lung densities were 0.275±0.387 and 0.270±0.383 respectively. The deviation in PBC calculated PDD were (+)216%, (+91%), (+)45%, (+)26.88%, (+)14%, (-)1%, (+)2%, (-)0.4%, (-)1%, (+)1%, (+)4%, (+)4.5% for 0.4 gm/cm3 and (+)311%, (+)177%, (+)118%, (+)90.95%, (+)72.23%, (+)55.83% ,(+)38.85%, (+)28.80%, (+)21.79%, (+)15.95%, (+)1.67%, (-) 2.13%, (+)1.27%, (+)0.35%, (-)1.79%, (-)2.75% for 0.2 gm/cm3 density mediums at depths of 1mm, 2mm, 3mm, 4mm, 5mm, 6 mm, 7 mm, 8mm, 9mm,10mm, 15mm, 30mm, 40mm, 50mm, 80mm and 100 mm, respectively. Conclusion: Large variations in inter- and intra- lung density were recorded. PBC overestimated the dose at air/lung interface as well as inside lung. The results of Monte Carlo simulation can be used to assess the performance of other treatment planning systems used in lung cancer radiotherapy
Authors and Affiliations
T. Raj Verma, N. Kumar Painuly, S. Prasad Mishra, S. A. Yoganathan, M. L. B. Bhatt
Comparative Analysis of Wavelet-based Feature Extraction for Intramuscular EMG Signal Decomposition
Background: Electromyographic (EMG) signal decomposition is the process by which an EMG signal is decomposed into its constituent motor unit potential trains (MUPTs). A major step in EMG decomposition is feature extracti...
Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter
Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiatio...
Manipulation Effect on Lumbar Kinematics in Patients with Unilateral Innominate Rotation and Comparison with Asymptomatic Subjects
Background: Lumbar motion analysis is used as a clinical method in the diagnosis and treatment of low back pain (LBP). So far, no studies have shown if manipulating the sacroiliac joint (SIJ) will change spinal kinematic...
A Semi-Automatic Algorithm for Estimating Cobb Angle
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observ...
A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, e...