Experimental investigation on possible dependence of plastic zone size on specimen geometry
Journal Title: Frattura ed Integrità Strutturale - Year 2009, Vol 3, Issue 7
Abstract
In this investigation the extent of the plastic zone size ahead of a crack-tip in single edge notched tension (SENT), compact tension (CT) specimens has been examined experimentally by micro-hardness technique and by elastic-plastic finite element analyses at different applied load levels. The magnitudes of the plastic zone size (PZS), rp ahead of crack-tip in the investigated specimens have been compared using normalized J-integral (J/aσy, where, a-crack length and σy-yield stress of the material). The results show the dependence of PZS on specimen geometry due to varied in-plane crack-tip constraint. The results also demonstrate that the existing analytical models do not explain the experimental results of PZS satisfactorily.
Authors and Affiliations
S. K. Kudari, B. Maiti, K. K. Ray
A numerical study of squeeze-film damping in MEMS-based structures including rarefaction effects
In a variety of MEMS applications, the thin film of fluid responsible of squeeze-film damping results to be rarefied and, thus, not suitable to be modeled though the classical Navier-Stokes equation. The simplest w...
Effective properties of a new auxetic triangular lattice:an analytical approach
In this article we propose a new auxetic periodic lattice with negative Poisson's ratio which tends tothe limit ν=-1 under particular conditions. We have studied its generation and kinematic, and we give a fulldesc...
Effects of microstructure and crystallography on crack path and intrinsic resistance to shear-mode fatigue crack growth
The paper focuses on the effective resistance and the near-threshold growth mechanisms in the ferritic-pearlitic and the pure pearlitic steel. The influence of microstructure on the shear-mode fatigue crack g...
Synchrotron 3D characterization of arrested fatigue cracks initiated from small tilted notches in steel
High resolution synchrotron X-ray tomography has been used to obtain 3D images of arrested cracks initiated at small artificial defects located on the surface of cylindrical steel specimens subjected to mode I fa...
Development of biodegradable magnesium alloy stents with coating
Biodegradable stents are attracting the attention of many researchers in biomedical and materialsresearch fields since they can absolve their specific function for the expected period of time and then graduallydisa...