ICareTM Tonometry: Reliability and Validity in Diabetic Patients

Journal Title: Ophthalmology Research: An International Journal - Year 2016, Vol 6, Issue 4

Abstract

Purpose: Reliability and validity of ICareTM tonometer was evaluated for its accuracy on IOP measurements in diabetic patients and controls. Central and peripheral corneal pressures, within and between groups were compared. Methods: This is a prospective study conducted from March 2015 to June 2015 in a tertiary hospital. Group 1 included central and peripheral IOP measurements in diabetics, Group 2 included central and peripheral IOP measurements in controls, Group 3 composed of central IOP measurements in diabetics and controls, and Group 4 was peripheral IOP measurements in diabetics and controls. Statistical analysis was performed by MedCalc software. Results: Sixty eyes of 60 participants constituting 30 diabetics and 30 controls were recruited. Mean age in diabetics and controls was 52.63 (+/- 11.87) and 41.7 (+/- 16.53) years. Male to female ratio was 18 (60%) and 12 (40%) in diabetic group while 12 (40%) and 18 (60%) in control group. Mean central and peripheral IOP in diabetics was 15.20 (+/- 3.15) and 14.10 (+/- 3.95) mm of Hg. Mean central and peripheral IOP In controls was 13.97 (+/-2.70) and 13.73 (+/- 3.16) mm of Hg. Pearson coefficient (r) of -0.28, -0.19, 0.12 and 0.22 was found respectively for groups. Paired sample t test showed t values of 1.74, 0.45, -1.06 and -0.28 obtained respectively. Statistical significance was considered when p <0.05. Reliability of ICareTM tonometer was performed by calculating Cronbach’s alpha and intraclass correlation coefficient. Calculated Cronbach’s alpha was 0.44, 0.32, 0.22 and 0.37 respectively. Intraclass correlation coefficient of -0.27, -0.19, 0.12 and 0.22 as single measures were found respectively. ICareTM tonometer validity was determined by ROC curve and accuracy was calculated by AUC difference that revealed 0.23, 0.06, 0.14 and 0.35 respectively. Limits of agreement were evaluated by Bland-Altman difference plots. Conclusion: ICareTM tonometry reliably measured ocular pressures in all groups with comparable values. Diabetic central pressures were negatively correlated with controls. Central and peripheral pressures showed slightly higher values in diabetics compared to controls.

Authors and Affiliations

S. K. Prabhakar, A. Shamsiya Naaz, Anuj Kumar Singal, Raghavender Reddy Arra, Pooja A. Angadi, W. Ankush

Keywords

Related Articles

Ishihara Electronic Color Blindness Test: An Evaluation Study

Purpose: Evaluation of computer based color deficiency test. Materials and Methods: Two hundred and sixty seven volunteers have been checked using both traditional Ishihara plates and a computer diagnosis program using L...

To Study the Role of Conservative Management and to Evaluate Effectiveness of Syringing and Probing in Children with Congenital Nasolacrimal Duct Obstruction in a Tertiary Care Institution of Kashmir

The study aimed to find the role of conservative management and to evaluate effectiveness of syringing and probing in children with congenital nasolacrimal duct obstruction in a tertiary care institution of Kashmir. The...

Comparison of Ocular and Developmental Outcomes in Laser-and Bevacizumab-treated Infants with Retinopathy of Prematurity

Purpose: To compare vision and developmental outcomes in infants who were treated with intravitreal bevacizumab injection (IVB) versus laser for retinopathy of prematurity (ROP). Methods: Forty-two infants were enrolled...

A Safe, Efficacious and Cost Effective Way of Delivering Sub-Tenon’s Anaesthesia during Cataract Surgery

Aims: There are considerable pressures in various health economies at present to reduce costs whilst maintaining patient safety and clinical efficacy. We report a new simplified regime for the administration of Sub-Tenon...

Tachyphylaxis to ranibizumab in the Treatment of Age-related Macular Degeneration

Purpose: To assess the patients with exudative age-related macular degeneration (AMD) who develop tachyphylaxis to ranibizumab after intravitreal injections of ranibizumab (IVR). Methods: We reviewed the records of 115 e...

Download PDF file
  • EP ID EP327465
  • DOI 10.9734/OR/2016/30291
  • Views 90
  • Downloads 0

How To Cite

S. K. Prabhakar, A. Shamsiya Naaz, Anuj Kumar Singal, Raghavender Reddy Arra, Pooja A. Angadi, W. Ankush (2016). ICareTM Tonometry: Reliability and Validity in Diabetic Patients. Ophthalmology Research: An International Journal, 6(4), 1-11. https://europub.co.uk/articles/-A-327465