IMPLEMENTATION OF PULSED NQR RADIOSPECTROSCOPY METHODS ON FPGA

Abstract

A multi-functional programmer of pulse sequences for NQR Fourier spectrometer has been developed on the basis of FPGA. The experimental test results have shown that the device assures shaping of pulsed sequences necessary for the pursuance of relaxation research in the frequency range of 1–50 MHz. The proposed programmer allows shaping of one, two and multi-pulsed sequences which enables the experiments on measuring relaxation times using the methods of Hahn, Carr-Purcell, Meiboom-Gill, et al. Owing to a wide range of change in pulse lengths and the possibility of shaping various sequences, this programmer assures a change in parameters Т1, Т2, Т2. Digital shaping of pulse sequences implemented in the proposed product assures high stability and accuracy of all temporal relations. The programmer guarantees phase binding of high-frequency filling of video pulses to pulse fronts.

Authors and Affiliations

А. П. Саміла, Г. М. Розорінов, О. В. Гресь

Keywords

Related Articles

GAS SUPPLY ENERGY INSTALLATION

A gas-air power plant been created that allows receiving electricity from the kinetic energy of the gas-air flow blown by the working mechanism. With the help of a laboratory facility, a real opportunity is shown for con...

ANALYSIS OF THE ASPHALT LAYERS STRESS-STRAIN STATE OF FLEXIBLE PAVEMENT WHEN HER DESIGNS MODELLING

The article is devoted to modeling the asphalt-concrete layers stress-strain state of flexible pavement. For most of the materials used in the technique, plastic deformations only depend of the acting forces values and o...

DYNAMIC MODEL FOR PREDICTING SUSTAINABLE WORK OF LONGWALLS

The analysis and phase portraits of the extraction process from longwall at different stages of time have been made. It is determined that the transition from a stable mode of work to an unstable one occurs gradually. Th...

ANALYSIS AND RESEARCH OF THE MODEL OF INFORMATION SECURITY VIOLATOR FOR A SECURED INTERNET ACCESS NODE

The paper analyzes and researches the model of the information security violator for a secured Internet access node. The general classification of information security violators circulating in a secured Internet access n...

THERAPEUTIC DEVICES FOR THE TREATMENT OF ARTHROSIS AN ANKLE JOINT BY ULTRASOUND

In this article, the problems of the prevalence of such an illness in Ukraine as deforming arthrosis of the tibia joint (on the basis of state statistics) and therapeutic devices for the treatment of this disease with ul...

Download PDF file
  • EP ID EP578747
  • DOI -
  • Views 54
  • Downloads 0

How To Cite

А. П. Саміла, Г. М. Розорінов, О. В. Гресь (2018). IMPLEMENTATION OF PULSED NQR RADIOSPECTROSCOPY METHODS ON FPGA. Вчені записки Таврійського національного університету імені В. І. Вернадського. Серія: Технічні науки, 29(3), 66-73. https://europub.co.uk/articles/-A-578747