Intraoperative Flow Measurement of Saphenous Vein Graft: Transit Time Flowmetry Measurement Versus Free Flow Measurement

Journal Title: Journal of Cardiovascular Medicine and Surgery - Year 2019, Vol 5, Issue 1

Abstract

Background: According to European Association for Cardio-Thoracic Surgery (EACTS) and European Society of Cardiology (ESC) guidelines, Transit time flowmetry (TTFM) is recommended for intraoperative graft patency verification during coronary artery bypass grafting (CABG). Studies are done to find out the accuracy and precision of the TTFM technique to measure left internal mammary artery (LIMA) blood flow when compared to its free flow. But none of the studies have been done so far on saphenous vein graft (SVG) graft flow measurement accuracy and precision with TTFM technique when compared to free flow measurement. Methods: The TTFM flow measurement and free blood flows was evaluated in 48 SVG grafts in patients undergoing beating heart coronary artery bypass surgery (OPCABG) using SVG as one of a conduit. The measurements were done after doing proximal anastomosis of SVG to aorta and before doing distal coronary anastomosis. Simultaneous reading was taken with TTFM devise and free flow through the graft. Results:The TTFM reading and free flow measurement results difference where statistically not different. Conclusions: The difference between TTFM measurements and free flow measurements were statistically not significant. TTFM can be Taken as an accurate indicator of SVG flow during CABG with clinically acceptable precision.

Authors and Affiliations

Girish Gowda S. L.

Keywords

Related Articles

Transverse Split Sternotomy for Repair of Tetralogy of Fallot: Mid Term Results

Background: Mini-invasive pediatric cardiac surgery has been slow to gain pace due to limited surgical exposure and long learning curve. We started performing transverse sternal split (TSS) to improve surgical exposure w...

Cardiac Co-morbidities in Patients with Chronic Obstructive Pulmonary Disease: Prospective Observational Study

Introduction: Chronic obstructive pulmonary disease (COPD) is a major global health issue. COPD affects pulmonary vasculature as well as heart leading to the development of pulmonary artery hypertension (PAH), corĀ­pulmon...

Frequency of Non Obstructive Epicardial Coronary Arteries in Patients with Typical Cardiac Chest Pain

Background: Coronary angiography is often found to be normal in patients with typical cardiac chest pain. There is limited data from India on frequency of normal coronary angiogram in patients undergoing coronary angiogr...

Frequency of Fragmented QRS in Psoriasis: A Prospective Case Control Study

Background: Array of clinical studies showed the interlink between psoriasis and cardiovascular diseases. Fragmentation of QRS has been visualized during myocardial fibrosis in electro cardiogram. Objective: To evaluate...

Low Atrial Rhythm: A Friend or Foe

The patient is a 29-year-old male gynecology resident presented with on and off palpitation since last 10 years who is on irregular diltiazem therapy. He is normotensive, euglycemic and with no reversible cardiovascular...

Download PDF file
  • EP ID EP655372
  • DOI 10.21088/jcms.2454.7123.5119.2
  • Views 103
  • Downloads 0

How To Cite

Girish Gowda S. L. (2019). Intraoperative Flow Measurement of Saphenous Vein Graft: Transit Time Flowmetry Measurement Versus Free Flow Measurement. Journal of Cardiovascular Medicine and Surgery, 5(1), 11-14. https://europub.co.uk/articles/-A-655372