Investigation of Critical Core Formulation and Process Parameters for Osmotic Pump Oral Drug Delivery
Journal Title: AAPS PharmSciTech - Year 2014, Vol 15, Issue 1
Abstract
Push–pull osmotic pump (PPOP) tablets of a practically insoluble model drug were developed and the effect of various formulation and process parameters on tablet performance was evaluated in order to identify critical factors. The formulation factors such as the viscosity grade of polyethylene oxide as the primary polymer as well as the level and location of osmogen within the bilayer tablets led to a difference in performance of osmotic tablets and hence should be critically evaluated in the design of such dosage forms. Modification of granulation process, i.e., the granulating liquid composition or drying method of granules, did not impact the drug release from the osmotic tablets at the evaluated scale of this study. The influence of varying dose and aqueous solubility of other model drugs (i.e., theophylline, acetaminophen, and verapamil HCl) on the developed PPOP template was also investigated. Results showed that irrespective of the perceived complexity of development and manufacturing of osmotic pumps, the osmotic tablets in this study demonstrated a robust and yet flexible platform in accommodating different types of drug candidates, regardless of solubility, for the dose levels below 25% w/w of the pull layer formulation.
Authors and Affiliations
Shahrzad Missaghi, Piyush Patel, Thomas P. Farrell, Hiep Huatan, Ali R. Rajabi-Siahboomi
Self-Nanoemulsifying Drug Delivery System of Nifedipine: Impact of Hydrophilic–Lipophilic Balance and Molecular Structure of Mixed Surfactants
A simple but novel mixed surfactant system was designed to fabricate a self-nanoemulsifying drug delivery system (SNEDDS) based on hydrophilic–lipophilic balance (HLB) value. The impacts of HLB and molecular stru...
Dissolution Testing for Bioavailability of Over-the-Counter (OTC) Drugs—a Technical Note
Thermoforma Orbital Shaker (420-4, Waltham, MA) was used to shake sample solutions at 100 RPM and 37°C. Orion pH Meter (710-1, Pittsburgh, PA) was used to measure solution pH. Two-point calibration with p...
Determining the Polymer Threshold Amount for Achieving Robust Drug Release from HPMC and HPC Matrix Tablets Containing a High-Dose BCS Class I Model Drug: In Vitro and In Vivo Studies
It is challenging to achieve mechanically robust drug-release profiles from hydrophilic matrices containing a high dose of a drug with good solubility. However, a mechanically robust drug release over prolonged period of...
Defining the Critical Material Attributes of Lactose Monohydrate in Carrier Based Dry Powder Inhaler Formulations Using Artificial Neural Networks
The study aimed to establish a function-based relationship between the physical and bulk properties of pre-blended mixtures of fine and coarse lactose grades with the in vitro performance of an adhesive active pharmaceut...
Hydrogels Composed of Cyclodextrin Inclusion Complexes with PLGA-PEG-PLGA Triblock Copolymers as Drug Delivery Systems
Although conventional pharmaceuticals have many drug dosage forms on the market, the development of new therapeutic molecules and the low efficacy of instant release formulations for the treatment of some chronic disease...