Investigation of Differential Pressure Flowmeters Accuracy in Pulsating Flows

Journal Title: Energy Engineering and Control Systems - Year 2016, Vol 2, Issue 1

Abstract

This work deals with the investigation of influence of flow pulsation on the accuracy of gas flowrate and volume measurement by means of the differential pressure flowmeters. Experimental studies of the step response curves of an impulse line with a pressure transducer (PT) were carried out with application of a high-frequency analog-to-digital converter of the pressure signal in the PT chamber. Mathematical model of an impulse line with a PT was built. This model provides simulation and investigation of the transient processes with high accuracy. The influence of the impulse line design (length, diameter) on the step response curves and on the frequency response curves as well as on the resonant frequency of the oscillating system (an impulse line with a PT chamber) was studied. The systematic errors of flowrate and volume measurement due to the resonance in the impulse lines which was caused by flow pulsation were simulated and studied for an acting differential pressure natural gas metering system. On the basis of the calculation results, it was defined that amplification of the amplitude of the oscillating signal of the differential pressure due to the resonance may lead to a negative systematic error of gas volume measurement. The systematic errors of gas flowrate and volume measurement caused by the flow pulsation can be reduced by choosing the correct design of the impulse lines in order to avoid the resonance.

Authors and Affiliations

Roman Fedoryshyn, Fedir Matiko, Ihor Kostyk, Yevhen Pistun

Keywords

Related Articles

Virtual Source of Reactive Power in Electricity Supply Systems of Household Consumers

It is proposed to include the principle of distributed generation of reactive power in the basic principles of constructing smart microgrids for non-commercial facilities. Individual reactive power compensation devices s...

Modeling of Hydraulic Load of Electric Drive in Electrical Complex of Pumping Station

The paper analyses the contemporary state of the electric drive hydraulic load modelling in the pumping stations’ electrotechnical complex applications. It was found that in the vast majority of cases, mathematical model...

Switching on Power Harmonic Filters

In modern industrial power supply systems, there is observed rapid growth of time varying nonlinear loads having low power factor. The most adequate engineering solution for reactive power compensation of the loads is us...

Research and Analysis of Rapidly Changing Gas Flow Temperatures Measurement Methods

The temperature of a transducer sensitive element, as a result of its heat capacity, will always lag behind the temperature of the gas flow if this temperature changes. When measuring the flow temperature that varies in...

Microwave Device for Obtaining Extracts from Plant Materials

A method for obtaining biopesticides from plant materials based on application of a microwave electromagnetic field in the process of extraction is being studied. The article presents results of an experimental study of...

Download PDF file
  • EP ID EP256959
  • DOI 10.23939/jeecs2016.01.009
  • Views 96
  • Downloads 0

How To Cite

Roman Fedoryshyn, Fedir Matiko, Ihor Kostyk, Yevhen Pistun (2016). Investigation of Differential Pressure Flowmeters Accuracy in Pulsating Flows. Energy Engineering and Control Systems, 2(1), 9-18. https://europub.co.uk/articles/-A-256959