Investigation of Differential Pressure Flowmeters Accuracy in Pulsating Flows
Journal Title: Energy Engineering and Control Systems - Year 2016, Vol 2, Issue 1
Abstract
This work deals with the investigation of influence of flow pulsation on the accuracy of gas flowrate and volume measurement by means of the differential pressure flowmeters. Experimental studies of the step response curves of an impulse line with a pressure transducer (PT) were carried out with application of a high-frequency analog-to-digital converter of the pressure signal in the PT chamber. Mathematical model of an impulse line with a PT was built. This model provides simulation and investigation of the transient processes with high accuracy. The influence of the impulse line design (length, diameter) on the step response curves and on the frequency response curves as well as on the resonant frequency of the oscillating system (an impulse line with a PT chamber) was studied. The systematic errors of flowrate and volume measurement due to the resonance in the impulse lines which was caused by flow pulsation were simulated and studied for an acting differential pressure natural gas metering system. On the basis of the calculation results, it was defined that amplification of the amplitude of the oscillating signal of the differential pressure due to the resonance may lead to a negative systematic error of gas volume measurement. The systematic errors of gas flowrate and volume measurement caused by the flow pulsation can be reduced by choosing the correct design of the impulse lines in order to avoid the resonance.
Authors and Affiliations
Roman Fedoryshyn, Fedir Matiko, Ihor Kostyk, Yevhen Pistun
Gas-dynamic Analyzer of Nitrogen-hydrogen Mixture for Industrial Application
Mathematical model of gas-dynamic analyzer of nitrogen-hydrogen mixture built on bridge throttle scheme using laminar-turbulent and turbulent-laminar throttle dividers is developed in the paper. The developed analyzer ha...
Investigation of Sensor for Measurement of Rotation Angle of Sensitive Element in Rotational Paper Pulp Consistometer
This paper presents the results of theoretical and experimental testing of an optical rotation angle sensor of rotational paper pulp consistency meter. It is suggested that a specialized device consisting of two discs wi...
The Energy Efficiency of the Solar Heating System with Combined Solar Collector
This article analyzes the influence of transparent coating on the efficiency of the combined solar collector. The prospects of solar heating systems’ usage, their main problems and their solutions are described. Heat of...
Algorithmic Method for Precision Enhancement of Paper Pulp Blade Consistometer
The article deals with the algorithmic method for precision enhancement of paper pulp blade consistometers . In the said method, the current strength in the winding of a moving coil of a magnetoelectric transducer in the...
Investigation of Mill Balls Metal Deterioration in Mills KBM 370/850 (Sh-50А) when Fuel not Envisaged in the Mill Design is Used at Thermal Power Plants
Method for determining mill balls metal deterioration rate in a ball mill KBM 370/850 (Sh-50А) of dust-system of coal-dust boilers TPP-210А and TPP-312 300МW of thermal power plants is described in the paper. The researc...