Investigation of Differential Pressure Flowmeters Accuracy in Pulsating Flows

Journal Title: Energy Engineering and Control Systems - Year 2016, Vol 2, Issue 1

Abstract

This work deals with the investigation of influence of flow pulsation on the accuracy of gas flowrate and volume measurement by means of the differential pressure flowmeters. Experimental studies of the step response curves of an impulse line with a pressure transducer (PT) were carried out with application of a high-frequency analog-to-digital converter of the pressure signal in the PT chamber. Mathematical model of an impulse line with a PT was built. This model provides simulation and investigation of the transient processes with high accuracy. The influence of the impulse line design (length, diameter) on the step response curves and on the frequency response curves as well as on the resonant frequency of the oscillating system (an impulse line with a PT chamber) was studied. The systematic errors of flowrate and volume measurement due to the resonance in the impulse lines which was caused by flow pulsation were simulated and studied for an acting differential pressure natural gas metering system. On the basis of the calculation results, it was defined that amplification of the amplitude of the oscillating signal of the differential pressure due to the resonance may lead to a negative systematic error of gas volume measurement. The systematic errors of gas flowrate and volume measurement caused by the flow pulsation can be reduced by choosing the correct design of the impulse lines in order to avoid the resonance.

Authors and Affiliations

Roman Fedoryshyn, Fedir Matiko, Ihor Kostyk, Yevhen Pistun

Keywords

Related Articles

Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler

Reconditioning of the TP-100А boiler can be implemented via a number of engineering solutions, including a complete replacement of the heating surface of the primary and secondary steam superheating circuits, boiler drum...

Improvement of 6/10 kV Distribution Power Networks Efficiency

The study focuses on the ways to improve the operation efficiency of 6 kV and 10 kV distribution power networks on the example of the Horodok District Power Network, Lvivoblenergo PJSC (Ukraine). The main drawbacks of th...

Evaluation of Influence of Wall Slip on Measurement of Rheological Parameters by Means of a Hydrodynamic Measuring System

The technique for processing the output signals of hydrodynamic measuring system of rheological parameters of non-Newtonian fluids is presented in the paper. Hydrodynamic measuring system is built on four serially connec...

Drying of Antioxidant Composite Materials based on Table Beet

Reduction in the cost of energy in the food industry is an important challenge today due to increased prices. Drying process of plant material refers to the complex energy-intensive processes. Solution of this problem is...

Algorithmic Method for Precision Enhancement of Paper Pulp Blade Consistometer

The article deals with the algorithmic method for precision enhancement of paper pulp blade consistometers . In the said method, the current strength in the winding of a moving coil of a magnetoelectric transducer in the...

Download PDF file
  • EP ID EP256959
  • DOI 10.23939/jeecs2016.01.009
  • Views 75
  • Downloads 0

How To Cite