Investigation of faults in 0.4 – 10 Kv electrical power network in the šiauliai region

Journal Title: Jaunųjų mokslininkų darbai - Year 2013, Vol 40, Issue 2

Abstract

In this article the number of faults and interrupted customers, the interruption duration, and fault reasons of 0.4-10 kV grid lines of the Šiauliai region have been investigated. Reliability indicators of the electrical network of the Šiauliai region have been calculated. The analysis of operating data demonstrates that most faults occur in 0.4 kV grid lines, but more customers are interrupted in 10 kV grid lines. Faults elimination duration are twice shorter in 10 kV grid lines compared with 0.4 kV grid lines. Most faults occur in overhead lines both in 0.4 kV and 10 kV grid lines. The main fault reason, operator responsibility, occurs in almost the half of all interruptions. Calculations of reliability indicators demonstrate that mostly the electrical power supply is interrupted for customers in the Kelmė and Raseiniai districts. For the interrupted customer in the Raseiniai district, most electrical power interruptions occur. The average for one interruption duration is longest in the Kelmė district. According to the investigation results, the Kelmė district is the most unreliable district of the Šiauliai region in view of electrical power supply for the customers

Authors and Affiliations

Nerijus Šulčius, Donatas Blėdis

Keywords

Related Articles

Kokybės užtiktinimas dviračių gamybos įmonėje

Gaminio paklausa šiuolaikinėje rinkoje apibrėžiama optimaliu gaminio kokybės ir kainos santykiu. Gaminys turi atitikti standartuose apibrėžtus bei vartotojo suformuluotus reikalavimus saugumui, tikslumui, patikimumui, o...

Statistical analysis of working efficiency and quality of assembly process

Working efficiency and quality are closely linked to the assembly process. In the absence of one of these factors, i.e., if the productivity is high, but the production is of low quality or vice versa, the enterprise wil...

Peculiarities of Revitalization of City Centres in Transition Country: Comparison of Lithuanian and Foreign Experience

Many Lithuanian historic urban centers have deep historical roots reaching the Middle Ages and the formation of the Lithuanian state. In the 20th century many democratic and non-democratic countries had faced the need to...

GYVO ŽMOGAUS ATPAŽINIMAS VAIZDO ĮRAŠE NAUDOJANT ODOS SPALVOS KITIMĄ

Biometrinis žmogaus identifikavimas plačiai naudojamas įvairiose realiose programose. Tačiau viena iš didžiausių problemų identifikuojant žmogų – nustatyti, ar prieš kamerą yra gyvas žmogus, ar tik jo vaizdas (pvz., nuot...

The Discourse of Mobbing as Discrimination in Employee Relations

On the individual level the appearance of mobbing is influenced by insecurity of the employee, frustration, bad social competence. On the social level mobbing occurs due to long-lasting traditions and relations, bad skil...

Download PDF file
  • EP ID EP141586
  • DOI -
  • Views 78
  • Downloads 0

How To Cite

Nerijus Šulčius, Donatas Blėdis (2013). Investigation of faults in 0.4 – 10 Kv electrical power network in the šiauliai region. Jaunųjų mokslininkų darbai, 40(2), 117-119. https://europub.co.uk/articles/-A-141586