In this article the number of faults and interrupted customers, the interruption duration, and fault reasons of 0.4-10 kV grid lines of the Šiauliai region have been investigated. Reliability indicators of the electrical network of the Šiauliai region have been calculated. The analysis of operating data demonstrates that most faults occur in 0.4 kV grid lines, but more customers are interrupted in 10 kV grid lines. Faults elimination duration are twice shorter in 10 kV grid lines compared with 0.4 kV grid lines. Most faults occur in overhead lines both in 0.4 kV and 10 kV grid lines. The main fault reason, operator responsibility, occurs in almost the half of all interruptions. Calculations of reliability indicators demonstrate that mostly the electrical power supply is interrupted for customers in the Kelmė and Raseiniai districts. For the interrupted customer in the Raseiniai district, most electrical power interruptions occur. The average for one interruption duration is longest in the Kelmė district. According to the investigation results, the Kelmė district is the most unreliable district of the Šiauliai region in view of electrical power supply for the customers

Authors and Affiliations

Nerijus Šulčius, Donatas Blėdis

Keywords

Related Articles

 DIRECTIONS AND STRATEGIES OF REGIONAL COOPERATION IN THE 2012-2016 POLISH FOREIGN POLICY

 This article analyses priority directions of Poland in regional collaboration. It shows that Poland wants to strengthen its position in political unions by creating a common perspective of European integration. Pol...

Rankinio ir automatinio testavimo tyrimas

Šiame straipsnyje pateikiamos dvi metodikos, kuriomis įvertinama rankinio ir automatinio testavimo pastangos. Taikant šias metodikas buvo palyginta rankinio ir automatinio testavimo įtaka laikui ir kainai. Atliktas tyrim...

PEROKSIDAZE KATALIZUOJAMOS BISFENOLIO A OKSIDACIJOS REAKCIJOS, DALYVAUJANT FENOKSAZINO DARINIUI, TYRIMAS

Bisfenolis A (Bis A) yra itin kenksmingas žmonių sveikatai, todėl ieškoma būdų, kaip jį neutralizuoti. Rekombinantinė Coprinus cinereus peroksidazė (rCiP) bisfenolį A oksiduoja lėtai, tačiau pridėjus 3-(10H-fenoksazin-10...

Peculiarities of Revitalization of City Centres in Transition Country: Comparison of Lithuanian and Foreign Experience

Many Lithuanian historic urban centers have deep historical roots reaching the Middle Ages and the formation of the Lithuanian state. In the 20th century many democratic and non-democratic countries had faced the need to...

Spread and Expression of Bullying in Years of Adolescence

In this article rather a relevant for owr modern society and school problem – bullying among senior students – is being analysed. Students ofte encounter violence and most frequently one of its forms – bullying. Sufferin...

Download PDF file
  • EP ID EP141586
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

Nerijus Šulčius, Donatas Blėdis (2013). Investigation of faults in 0.4 – 10 Kv electrical power network in the šiauliai region. Jaunųjų mokslininkų darbai, 40(2), 117-119. https://europub.co.uk/articles/-A-141586