Lighting setting features of opto-electronic measuring system for controlling adhesive joints optical components

Abstract

Purpose: The purpose of this article is to study the features of setting and selecting the source of illumination of the optoelectronic measuring system for the control of adhesive joints of optical parts. Design/methodology/approach: The research and analysis of the lighting characteristics of halogen and LED lamps, used as a source of illumination in the measuring system, was carried out. Findings: In the course of experimental studies, the sensitivity and resolution of fixing defects of adhesive joints of optical parts were increased and the measurement error was reduced from 10 ± 1.2 microns to 10 ± 0.3 microns. Research limitations/implications: The limitations of the accuracy of the measurement are 10 ± 0.3 microns of adhesive defects, since the studies were conducted on separate samples of glues that did not cover all adhesives for the connection of optical surfaces and the thickness of glass surfaces was 1 mm and 2 mm. Practical implications: With the application of the lighting system approach described in the article, it is possible to improve any optoelectronic measuring system, thereby increasing the accuracy of the measurement. Originality/value: The originality of the results of the article is the experimental data of the studies of light-technical characteristics of the halogen lamp, which is used in the optoelectronic measuring system.

Authors and Affiliations

O. M. Markina

Keywords

Related Articles

Indexes

Indexes

Theoretical study of food contamination mechanisms by melamine and hazard of melamine for health

Purpose: The purpose of this investigation is to theoretical study of food contamination mechanisms by melamine and hazard of melamine for health. This purpose is justified as follows. A high percentage of nitrogen has c...

Design and analysis of salt collector

Purpose: Salt is one of the important cooking ingredients used in our daily life. TamilNadu is the second largest producer of salt in India, next only to Gujarat. The salt iscollected manually by the labours. Since, ther...

Substantiation of expedience of application of high-temperature utilization of used tires for liquefied methane production

Purpose: The purpose of this investigation is to substantiate by means of numerical simulation the expedience of high-temperature utilization of used tires with subsequent methanation of fuel gases and separation of mult...

Field tests of components regenerated using the MULTIPLEX technology

Purpose: The purpose was to show the results of the field tests of components carried outusing the MULTIPLEX technology.Design/methodology/approach: The field tests have been carried out on the followingcomponents: brake...

Download PDF file
  • EP ID EP249468
  • DOI 10.5604/01.3001.0010.7781
  • Views 99
  • Downloads 0

How To Cite

O. M. Markina (2017). Lighting setting features of opto-electronic measuring system for controlling adhesive joints optical components. Journal of Achievements in Materials and Manufacturing Engineering, 2(84), 49-57. https://europub.co.uk/articles/-A-249468