Management Of Intercondylar Fracture Of Femur With Periarticular Locking Plates And Evaluation Of Results By Sander’s Knee Scoring System

Abstract

Fractures of the distal femur are complex injuries that can be difficult to manage and though treatment has evolved in recent years the treatment of these fractures carry an inconsistent prognosis. LCP is a new type of implant system for the treatment of distal femoral fractures. A plate, precontoured to the anatomy, is inserted through a minimally invasive incision into the epiperiosteal space by means of an aiming device after indirect, closed fracture reduction. We have done a study on 20 patients with fracture of distal femur [either C2 OR C3 according to AO Classification3] fixed with LCP and analysed their result. We concluded that LCP is good option for managing of complex interarticular distal femur fractures but it has to be applied with proper understanding of biomechanics and respect to soft tissues.

Authors and Affiliations

Rohit Sharma, sachin Gupta

Keywords

Related Articles

Functional And Radiological Outcomes After Volar Locking Plate Fixation In Type C Distal Radius Fractures – A Retrospective Study

Background -Open reduction and internal fixation using a volar locking plate has gained popularity for the treatment of intraarticular distal radius fractures. Purpose -To evaluate the functional and radiological outco...

Evaluation of surgical fixation of paediatric diaphyseal long bone fractures in lower limb with elastic stable intramedullary nailing (esin)

Femoral shaft fractures account for 1.6% of all paediatric injuries. The best treatment for children between five to sixteen years of age is still questioned. Patients in this transitional age group have high risk of sho...

Management Of Fractures Of Distal Femur - Intra-Articular Type C2 By Locking Plate Or Condylar Buttress Plate

Background:- Intra articular fractures of distal femur is a great surgical challenge when associated with metaphyseal comminution (Type C 2) in terms of getting reduction and difficulty of maintaining reduction. Operativ...

Comprehensive study of giant cell tumor of bone in major hospitals in and around mangalore, karnataka

Even after so many years of research studies using modern imaging techniques and histopathological diagnosing methods, when we describe a giant cell tumor of bone everything revolves around a word ‘most common’. Present...

Evaluation of Diagnostic Accuracy of Machine Learning Algorithm for Computer Aided Diagnosis (CAD) of Space Occupying Lesions in Computed Tomography (CT) Images of Brain

Objectives-Objective of this project was to formulate a low cost and userfriendly SOL detection computational model through machine learning and test its diagnostic efficacy through retrospective evaluation of radiologis...

Download PDF file
  • EP ID EP394860
  • DOI -
  • Views 129
  • Downloads 0

How To Cite

Rohit Sharma, sachin Gupta (2017). Management Of Intercondylar Fracture Of Femur With Periarticular Locking Plates And Evaluation Of Results By Sander’s Knee Scoring System. International Journal of Orthopaedics Traumatology & Surgical Sciences, 3(1), 568-571. https://europub.co.uk/articles/-A-394860