Modified Setting Numerical Distance Protection Of Power Transmission Line In Presence of TCSC Using IEC 62850 Communication Protocol

Abstract

This paper presents a study of the performance of numerical distance relay for a 400 kV electrical transmission line compensated by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) is connected in the middle of the transmission line and can be used in voltage mode control or reactive power injection mode, and damping of power system oscillations in high power transfer levels. IEC 61850 is a new international standard for communication networks and systems in substations that defines different message types based on their transfer time requirements. In IEC 61850 based Substation Automation systems (SAS). The effect of the TCSC on the measured impedance at the relaying point is investigated. The setting zones protection deals with the absence and presence of TCSC using IEC 61850 communication protocol for two stations i.e. Principal station and TCSC station with proposed scheme for tele-protection for studies the effects of TCSC insertion on the total impedance of a transmission line protected by MHO distance relay and the modified setting zone rotection in capacitive and inductive mode for three forward zones (Z1, Z2 and Z3) have been investigated in order to prevent circuit breaker nuisance tripping to improve the performances of distance relay protection.

Authors and Affiliations

Mohamed ZELLAGUI, Abdelaziz CHAGHI

Keywords

Related Articles

Watermarking Based on the Hyperanalytic Wavelet Transform

In this paper we present a new technique for watermarking in the hyperanalytic wavelet domain. This has the advantage of better directional selectivity and shift invariance compared to the classical wavelet filter. The w...

Novel Current Line Sensor Based On Matched Optocouplers For Active Power Factor Correction

This paper presents a novel line current sensor which allows safe and accurate data acquisition for power factor measurements: it uses a pair of matched optocouplers arranged so that the difference between their outputs...

Bearing Defects Signals Demodulation Using Shock Filters

A fundamental problem in the development of faults detection and diagnoses methods is to obtain fault signature data as clear as is possible. This article is focused on vibration signals generated by rolling bearings wit...

TLS Protocol: Secure Protocol With Client Puzzles

Client puzzles are commonly proposed as a solution to denial-of-service attacks. We analyzed the TLS protocol and implement Client Puzzles algorithm. We pursued the following objectives: analyze TLS handshake protocol...

Aspects of Algorithm Development for Systems With Online Detection and Recognition of TV Commercials

The paper describes a series of research stages in the development process for an automated system, able to detect commercial brakes in TV signals, and recognize a basic set of logos form the TV commercials. First, the c...

Download PDF file
  • EP ID EP87184
  • DOI -
  • Views 138
  • Downloads 0

How To Cite

Mohamed ZELLAGUI, Abdelaziz CHAGHI (2012). Modified Setting Numerical Distance Protection Of Power Transmission Line In Presence of TCSC Using IEC 62850 Communication Protocol. Acta Technica Napocensis- Electronica-Telecomunicatii (Electronics and Telecommunications), 53(3), 16-24. https://europub.co.uk/articles/-A-87184