DEVELOPMENT AND VALIDATION OF HPLC METHOD FOR DETERMINATION OF ROXITHROMYCIN FROM HUMAN PLASMA

Journal Title: Int J of Preclin & Pharm Res - Year 2014, Vol 4, Issue 1

Abstract

 ABSTRACT A stable, simple, rapid, precise, accurate HPLC method for analysis of Roxithromycin was developed and validated as per ICH guidelines without need of any internal standard. Separation was carried out using X’terra RP18 (250*4.6) mm, 5µ column with potassium dihydrogen orthophosphate buffer (pH 3): acetonitrile (30:70 v/v) as mobile phase with flow rate 1 mL min-1 . The parameters studied were retention time, linearity and range, accuracy, precision. The proposed method can be used for determination of Roxithromycin from Human plasma. Keywords: Roxithromycin, HPLC, Validation

Authors and Affiliations

*Rajesh Chaudhari

Keywords

Related Articles

 FINGERPRINT ANALYSIS OF HERBAL MEDICINES USING HPLC: AN OVERVIEW

 ABSTRACT Fingerprint analysis approach using HPLC has become the most potent tools for quality control of herbal medicines because of its simplicity and reliability. It can serve as a tool for identification, au...

 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION AND STABILITY STUDIES OF THE ESTIMATION OF AGOMELATINE IN TABLET DOSAGE FORM BY RP-HPLC

 ABSTRACT Agomelatine is a new melatonergic antidepressant with a unique pharmacological action. A stability indicating RP-HPLC method was developed and validated for the determination of agomelatine in active pharm...

 DEVELOPMENT AND VALIDATION OF UV SPECTROPHOTOMETRIC METHOD FOR QUANTITATIVE ESTIMATION OF CEFTAROLINE FOSAMIL IN BULK AND INJECTION FORM

 ABSTRACT Two simple, sensitive, specific, spectrophotometric methods have been developed for the determination of ceftaroline fosamil in bulk and Injection forms. The λmax of ceftaroline fosamil was found to be 2...

 DEVELOPMENT AND VALIDATION OF STABILITY INDICATING RP-HPLC METHODFOR SIMULTANEOUS ESTIMATION OF ATORVASTATIN AND OLMESARTAN IN PHARMACEUTICAL DOSAGE FORM

 ABSTRACT A simple, precise, rapid, specific and accurate stability indicating reverse phase high performance liquid chromatography method was developed for simultaneous estimation of Atorvastatin (ATV) and Olmesart...

 RECENT APPROCHES FOR IMPURITY PROFILING IN PHARMACEUTICAL FORMULATIONS

 ABSTRACT In the pharmaceutical world, an impurity is considered as any other organic material, besides the drug substance, or ingredients, arise out of synthesis or unwanted chemicals that remains with API’s. The...

Download PDF file
  • EP ID EP128377
  • DOI -
  • Views 104
  • Downloads 0

How To Cite

*Rajesh Chaudhari (2014).  DEVELOPMENT AND VALIDATION OF HPLC METHOD FOR DETERMINATION OF ROXITHROMYCIN FROM HUMAN PLASMA. Int J of Preclin & Pharm Res, 4(1), 1-6. https://europub.co.uk/articles/-A-128377