Utilization of DVR with FLC to Inject Voltage in a Transmission Line

Journal Title: International Journal of Modern Engineering Research (IJMER) - Year 2013, Vol 3, Issue 4

Abstract

 In this paper a Dynamic Voltage Restorer (DVR) is used for power quality improvement on transmission side for the voltage regulation, grid stabilization and efficient utilization. The DVR normally installed between the source voltage and critical or sensitive load. The vital role of DVR depends on the ef iciency of the control technique involved in switching circuit of the inverter. The DVR is controlled by using PI with fuzzy logic controller. The Fuzzy logic controller based on fuzzy logic provides a means of converting a linguistic control strategy based on expert knowledge into automatic control strategy. This paper presents a Digital validation conducted for different cases of fault conditions using the Mat lab/Simulink/Sim-Power software environment with the Dynamic Voltage Restorer scheme with fuzzy controller for ef ective voltage compensation, in rush current conditions and transmission line loss reduction.

Authors and Affiliations

R. Udaya Sree

Keywords

Related Articles

 Prospective Evaluation of Intra operative Nucleus 22-channel cochlear implant Radiographs

 To investigate the clinical utility of intra operative plain radiographs in cochlear implant surgery. Eighty consecutive adult and pediatric cochlear implant operations at a facility capable of intra operative ra...

 Spectrophotometric Determination of Cardiovascular Drugs

 Simple, sensitive, accurate and precise spectrophotometric methods for quantitative determination of cardiovascular drugs viz., Dobutamine Hydrochloride (DOB), Ramipril (RAM), Telmisartan (TEL), Verapamil Hydroch...

Measurement of Total and Partial Mass Attenuation Coefficients of Oxide Glasses: A Radiation field

The variation in mass attenuation coefficient µ for total and partial photon interaction processes for three different oxide glasses (65CaO-35Al2O3(OG1) , 20Na2O-80SiO2(OG2), and 20Na2O-5Al2O3-75SiO2 (OG3)), in the incid...

 A New Bi-level Program Based on Unblocked Reliability for a Continuous Road Network Design

 With increasing demands for better and more reliable service, developing a method for designing a highly-reliability road network has become a critical issue. A Network Design Problem is used to determine a set...

Simulation and Development of Stepper Motor for Badminton Playing Robot

The development of digital electronics and microprocessor systems has the advantage to the development of electric motor capable to be digitally controlled. In this paper stepper motor is used to control positi...

Download PDF file
  • EP ID EP120544
  • DOI -
  • Views 116
  • Downloads 0

How To Cite

R. Udaya Sree (2013).  Utilization of DVR with FLC to Inject Voltage in a Transmission Line. International Journal of Modern Engineering Research (IJMER), 3(4), 2389-2395. https://europub.co.uk/articles/-A-120544