New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 1

Abstract

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy function which leads to unsatisfactory results. Objective: We propose in this paper a new approach for the generation of a pseudo-CT image from an MR image. Materials and Methods: This approach is based on a dense stereo matching concept, for that, we encode each pixel according to a shape related coordinates method, and we apply a local texture descriptor to put into correspondence pixels between MRI patient and MRI atlas images. The proposed approach was tested on a real MRI data, and in order to show the effectiveness of the proposed local descriptor, it has been compared to three other local descriptors: SIFT, SURF and DAISY. Also it was compared to registration method. Results: The calculation of structural similarity (SSIM) index and DICE coefficients, between the pseudo-CT image and the corresponding real CT image show that the proposed stereo matching approach outperforms a registration one. Conclusion: The use of dense matching with atlas promises good results in the creation of pseudo-CT. The proposed approach can be recommended as an alternative to registration techniques.

Authors and Affiliations

H. Chaibi, R. Nourine

Keywords

Related Articles

Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound

Background Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic s...

The Effect of Long-Term X-Ray Exposure on Human Lymphocyte

The aim of the paper is to investigate effects of long term x-ray exposure on the human lymphocyte, reactive lymphocyte parameters and morphology of lymphocytes in x-ray technicians at Kirkuk hospitals. The study include...

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis o...

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support...

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may n...

Download PDF file
  • EP ID EP453499
  • DOI -
  • Views 86
  • Downloads 0

How To Cite

H. Chaibi, R. Nourine (2018). New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor. Journal of Biomedical Physics and Engineering, 8(1), 53-64. https://europub.co.uk/articles/-A-453499