On the Immunity of Data Acquisition Systems Used in Power Systems

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2016, Vol 40, Issue 40

Abstract

The paper deals with some tests regarding the immunity for radiated emissions and compliance with international standards for electromagnetic compatibility (EMC) measurements for an industrial data acquisition system (DAS) used in power systems. The behavior of the DAS, when functioning near electromagnetic disturbance sources, is studied. The goal is to test its robustness in similar conditions as those encountered in its normal environment. It is known that multiple factors may affect the accuracy of data acquired by DAS. The Equipment Under Test (EUT), witch in this case is represented by DAS is tested for immunity in a specialized enclosure (GTEM Cell). The immunity based on the analysis of the influences of an electric field with constant magnitude and variable frequency in the range of 80 MHz…1 GHz is studied. After analyzing the initial tests results, partial and, afterwards, full shielding of the EUT’s case is performed in order to remove the EM influence. The tests’ results drive to the conclusion that it is necessary to design and build an enclosure from conductive material for the DAS. After the implementation of the measures, the EUT passed the tests concerning the immunity. The GTEM Cell construction, GTEM model, generation and distribution of electric and magnetic field inside the GTEM Cell, equipment under test (EUT), radiated emission measurement scheme, EMC standards for GTEM Cell, are exposed.

Authors and Affiliations

Livia-Andreea Dina, ILeana-Diana Nicolae, Petre-Marian Nicolae, Dorina-Mioara Purcaru

Keywords

Related Articles

 Aspects Regarding Influences of Voltage and Resistant Torque on Asynchronous Motors Operation

 In this paper there are analyzed a series of dynamic regimes that occur in the case when a phase of an asynchronous motor is accidentally interrupted and in the case when the resistant torque increases by step. For...

 Factors Involved in Choosing LEDs for General Lighting Applications: a Critical Review

 Electric lighting accounts for 19% of electricity consumption worldwide and generates remarkable concern to get energy savings. As a modern source of light, LEDs open up a multitude of innovative lighting solutions...

Diagnosis with Analytic Model of a Rectifier for Faults of the Rectifier Control

The diagnosis of the electric systems is an actual item for the specialists in domain. Due to the variety of the measurements and multiplicity of faults which can be analyzed, the approach is motivating. The model reprod...

MICRO-HYDROPOWER STATION FOR KINETIC ENERGY CONVERSION OF FLOWING WHATER

An efficient conversion of kinetic energy of river water into mechanical or electrical energy without building barrages is provided by micro-hydropower stations. Increased efficiency is achieved by an optimum position of...

 Magneto-Thermal Model for Crimped Connections

 In this paper numerical results coresponding to thermal regime of two types of superposed crimped connections has been obtained. The samples studied use copper wire crimped by two methods: the first method uses...

Download PDF file
  • EP ID EP263669
  • DOI -
  • Views 113
  • Downloads 0

How To Cite

Livia-Andreea Dina, ILeana-Diana Nicolae, Petre-Marian Nicolae, Dorina-Mioara Purcaru (2016). On the Immunity of Data Acquisition Systems Used in Power Systems. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 40(40), 147-152. https://europub.co.uk/articles/-A-263669