Abstract

This paper presents a methodology to determine optimal location and size of DG so as to minimize real/active power loss in the distribution network. For this purpose, suitable expressions have been derived to compute the active power loss saving associated with placement of the DG units. The proposed method is applicable for sizing and siting of single DG unit at a time. Moreover, the proposed method requires only the results of base case load flow to determine the optimal size of DG unit. The proposed method is tested on 33-bus and 69-bus radial distribution test systems. The comparison of results obtained by the proposed method with those of reported methods validate the suitability and importance of proposed method in determining the optimal size and site of DG unit.

Authors and Affiliations

Gopiya Naik . S, D. K. Khatod, M. P. Sharma

Keywords

Related Articles

A Review on the Need for Investigating Space Charge Behavior in Multi-Layered Polymeric Dielectrics

The benefit of using HVDC system is partially reduced due to space charge accumulation in the insulation as the space charge has capability of enhancing the local electric field in the dielectric. Research indicates that...

Hierarchical Steady State Control of System wide Distributed Multi-FACTS Devices for Operational Enhancement Objectives

Developed power systems in the world are well meshed with local, inter-regional and international connection making the increasing complex to operate. With advancement in power electronics, the control of these systems a...

Analysis and Development of a Reliability Forecasting Model for Injection Substation

This paper is aimed at analyzing and developing a reliability forecasting model for an Injection Substation; a case study of Ugbowo 33/11kV Injection Substation. This project seeks to determine the current reliability st...

Lightning Protection as Per IEC 62305 & Key Factors of Installation, Maintenance

The basic interest of this paper is to discuss and insist on the importance of protection devices / system and to regulate the overall process including selection, installation and upkeep of the lightning protection syst...

Constant voltage and Constant frequency operation of DFIG using Lab view FPGA and cRIO

This paper presents control of doubly fed induction generator using LabVIEW FPGA platform. NI LabVIEW FPGA enables fast and easy implementation of hardware control due to its graphical programming capability, inherent pa...

Download PDF file
  • EP ID EP388577
  • DOI 10.9790/1676-1301024253.
  • Views 141
  • Downloads 0

How To Cite

Gopiya Naik . S, D. K. Khatod, M. P. Sharma (2018). Optimal Siting and Sizing of Dg in Distribution Networks for Power Loss Saving. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 42-53. https://europub.co.uk/articles/-A-388577