Overloading coefficients of cantilever span support
Journal Title: Roads and Bridges - Drogi i Mosty - Year 2010, Vol 9, Issue 2
Abstract
Safety analysis of cantilevered bridges can be applied to spans and supports. The paper concerns effects of overloading of temporary supports, usually used for erecting concrete cantilevered spans. Influence of selected factors is considered on the example of bridge, built in Kędzierzyn-Koźle. The length of the main span of this prestressed concrete box girder bridge is 140 m. Supports of the structure are loaded untypically, due to skewness of the bridge. Proposed span overloading coefficients are used for evaluation of structure safety in erection stage. In the paper design solutions of dead load asymmetry (arrangement of cable anchorages along the span length), influence of random factors (segment cross-section dimensions assumed as random variables) and segment concreting asymmetry are considered. Different coefficients of segment and cantilever overloading are distinguished. The first one usually have greater values, than calculated on their basis global value for the whole cantilever.
Authors and Affiliations
Czesław Machelski, Robert Toczkiewicz
Reinforced concrete viaduct from beginning of the 20th century – microstructure analysis of 100 years old concrete
In the paper the history of a viaduct from Railway Warsaw - Kalisz and its present condition is described. The parabolic vaulted viaduct that was built for the Railway Warsaw - Kalisz, is probably one of two oldest concr...
Design principles and testing of internal frost resistance of concrete for road structures - critical review
We present a review of freeze-thaw durability requirements laid down in both European standards and in the national specifications in relation to concrete for road structures. The principles of material selection for con...
Design of geosynthetic reinforcements for earth structures in line with regulations of Eurocode 7
The paper presents design rules of geosynthetic reinforcements based on the regulation of EC 7 with the adaptation to the Polish conditions are presented. Especially, the recommendations given in the Instruction 429/2007...
Badania w czasie zasypywania gruntowo-powłokowej konstrukcji o dużej rozpiętości wykonanej bez dodatkowych elementów usztywniających
W pracy przedstawiono wyniki badań polowych prototypowej konstrukcji, w postaci niskoprofilowego łuku stalowego wykonanego z blach falistych, zabudowanego w gruncie, służącej w zamyśle jako przejście dla zwierząt. Omawia...
Friction coefficient, texture depth and tyre/road noise evaluation method by analysis of tyre print image
The development of road network requires intensive research in the field of road maintenance. It is essential to develop efficient and effective assessment methods of road pavement condition. Monitoring the level of the...