PADC Detected External Neutron Field by Nuclear Tracks at RFX-mod

Abstract

Measured neutron signals relevant for plasma diagnostics on Reversed Field pinch eXperiment, RFX-mod, are obtained by nuclear track methodology with PADC-NtD’s. this technique provides the external neutron field values around the RFX-mod installation during pulsed operation. Charged particles from (n, p) and (n, α) reactions are related to formed latent tracks. these are etched in a thermoregulated water bath with a 6.25M, KOH solution at 60oC. Observed tracks were analyzed to determine track density from which neutron fluence spatial values should be derived. Results indicate that the neutron density in the surrounding environment change at most 40%. the epithermal component is 60% higher than that corresponding to the thermal region. the estimated neutron fluence for the whole experiment is 7.5×1010 neutrons cm2/s.

Authors and Affiliations

W. Gonzalez, G. Espinosa, M. Zuin, F. Pino, J. I. Golzarri, E. Martines, J. Bermudez, D. Moro, J. K. Palfalvi, L. Sajo-Bohus

Keywords

Related Articles

Quantum Effects on the Linear Dispersion Characteristics in Electron-Positron Plasma

In electron-positron plasmas some of the plasma modes are decoupled due to the equal charge to mass ratio of both species. The dispersion properties of the propagation of linear waves in degenerate electron–positron magn...

Theoretical Model to Estimate the Distribution of Radon in Alveolar Membrane Neighborhood

Radon is a naturally occurring radioactive gas which tends to concentrate indoors, easily emanates from the ground into the air, where it disintegrates and emits radioactive particles. It can enter the human body through...

Characterization Of Structures Of Equivalent Tissue With a Pixel Detector

Research using hybrid pixel detectors in medical physics is on the rise. Timepix detectors have arrays of 256 × 256 pixels with a resolution of 55 µm. Here, and by using Timepix counts instead of Hounsfield units, we pre...

Experimental Setups for Single Event Effect Studies

Experimental setups are being prepared to test and to qualify electronic devices regarding their tolerance to Single Event Effect (SEE). A multiple test setup and a new beam line developed especially for SEE studies at t...

Enhancement in the Photoluminescence Properties of SiO2:Ge Embedded in a Polymeric Matrix

Polymer films of styrene butadiene copolymer (SBC) mixed with SiO2:Ge powder were successfully obtained by the drop casting method. The SBC concentration (in chloroform solution) was 10%w/v and the SiO2:Ge powder was mix...

Download PDF file
  • EP ID EP593506
  • DOI 10.15415/jnp.2014.21006
  • Views 250
  • Downloads 0

How To Cite

W. Gonzalez, G. Espinosa, M. Zuin, F. Pino, J. I. Golzarri, E. Martines, J. Bermudez, D. Moro, J. K. Palfalvi, L. Sajo-Bohus (2014). PADC Detected External Neutron Field by Nuclear Tracks at RFX-mod. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 2(1), 83-90. https://europub.co.uk/articles/-A-593506