Placement of Phasor Measurement Units in Power Networks and Optimal Distribution of Measurement Redudancy

Journal Title: روش های هوشمند در صنعت برق - Year 2018, Vol 9, Issue 36

Abstract

In this paper, in addition to optimal placement of phasor measurement units (PMUs) a new method is proposed for optimal distribution of measurements redundancy. Since the buses having first order redundancy degrade the system observability by missing their measurements, this method is used to reduce the number of these. On the other hand, the proposed method, in spite of the previous methods, is used to enhance the system observability by improving the redundancy order of the other low order redundancy buses without increasing the number of the lower orders. .In addition, by using this method, the optimal PMU placement can be obtained considering the contingencies such as PMU outage or line outage. It should be noted that the proposed methods are implemented on the IEEE 14-, 30, 57- and 118- bus power networks. The simulation results are compared with previous methods. In addition, simulations are performed with and without considering the effect of zero injection buses.

Authors and Affiliations

Ali Ansari, Fariborz Haghighatdar Fesharaki

Keywords

Related Articles

A New Layout for English Letters on the Keyboard Using Evolutionary Strategy

Since the keyboard is the primary device of entering text into a computer, a keyboard with letters on the proper layout of high performance is essential. Obtaining a suitable arrangements for the letters on the keyboard...

Fractional Order PID Controller Design for Level Control of Three Tank System Based on Improved Cuckoo Optimization Algorithm

Fractional-order PID (FOPID) controller is a generalization of standard PID controller using fractional calculus. Compared with the Standard PID controller, two adjustable variables “differential order” and “integral or...

Wavelet Packet Entropy in Speaker-Independent Emotional State Detection from Speech Signal

In this paper, wavelet packet entropy is proposed for speaker-independent emotion detection from speech. After pre-processing, wavelet packet decomposition using wavelet type db3 at level 4 is calculated and Shannon entr...

Design and Implementation of an Optimal PV Refrigeration System in the Smart Grid Considering Multi-objective Optimization

Today, optimization in power systems is an unavoidable necessity. Energy intensity reduction in electrical devices and enhancement of their efficiency and performance, electricity loss reduction and voltage profile impro...

Design and Fabrication of Novel Single- and Dual-band Bandpass Filters with Modern Zero-Degree Feed Structure for Wireless Communications

In this paper, there are three novel bandpass filters (BPFs), consist of single- and dual-band, presented in a same size, which all the filters, have been designed, optimized and finally fabricated and measured, based on...

Download PDF file
  • EP ID EP569310
  • DOI -
  • Views 83
  • Downloads 0

How To Cite

Ali Ansari, Fariborz Haghighatdar Fesharaki (2018). Placement of Phasor Measurement Units in Power Networks and Optimal Distribution of Measurement Redudancy. روش های هوشمند در صنعت برق, 9(36), 3-14. https://europub.co.uk/articles/-A-569310