Platelet-rich plasma collection and preparation: a retrospective analysis of 256 cases

Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 10

Abstract

Objective To retrospectively analyze the safety and product quality of NGL XCF 3000 blood cell separator for collecting platelet-rich plasma (PRP) in 256 cases, so as to provide reference for safe collection and product quality control of PRP. Methods The data of 256 patients receiving PRP treatment in our hospital from June 2021 to June 2022 were statistically analyzed, and the differences in the collection time, circulating blood volume and the occurrence of adverse reactions to blood donation were analyzed when NGL XCF 3000 was used to collect autologous PRP among patients of different genders, ages and platelet counts. The differences in platelet content, red blood cell(RBC) contamination and white blood cell(WBC) residues in PRP products were analized. Results 1) There were no significant differences in collection time, circulating blood volume and collection volume among patients of different genders, ages and platelet counts (P<0.05). 2) The contents of WBC, RBC and platelet were not significantly different between male and female patients after collection (P<0.05); 3) The WBC contents increased with the increase of age, and the WBC residue in the elder group[ 56 to78 years old, (0.64±0.41) ×109/L] was significantly higher than that in the younger group[group 1,18 to 40 years old, (0.50±0.35)×109/L], with significant difference was Statistically significant (P<0.05). 4) The residues of WBCs and RBCs in in low platelet group [group 1, (100-150)×109/L] were higher than those in other platelet count groups, and the difference was Statistically significant (P<0.05), and the platelet count in this product was significantly lower than that in other platelet count groups (P<0.05). Conclusion The NGL XCF 3000 blood cell separator is safe and stable for PRP collection in patients with different genders, ages and platelet counts of (100-450)×109/L, and the PRP products collected can meet clinical therapeutic needs.

Authors and Affiliations

Lijuan YANG, Yan HU, Yajuan WU, Li ZHANG, Liping LIU, Tao PENG, Xinyu GAN

Keywords

Related Articles

Frequency of double population of Rh blood group C and E antigen after transfusion of allogeneic red blood cells and its influence on blood transfusion efficacy

Objective To prove the necessity of precise red blood cell transfusion by studying the frequency of double population of Rh blood group C and E antigen after allogeneic red blood cell transfusion in our hospital and its...

Changes and distribution of antibodies in plasma before and after infection of SARS-CoV-2 Omicron strain

Objective To determine the best collection time period of plasma which can be used for human COVID-19 immunoglobulin for intravenous injection through SARS-CoV-2-IgG change and neutralizing antibody distribution against...

Establishment of Shaanxi rare blood group information supply platform

Objective To establish a rare blood group information supply platform in Shaanxi Province. Methods The rare blood group information supply platform consists of sample registration, result registration, donor files and in...

Establishment of human monoclonal hybridoma cell lines specific for PP1Pk antigens from peripheral B lymphocytes of a p[Tj(a-)] donor

Objective To establish lymphoblastoid cell line (LCL) and human monoclonal antibody cell lines against PP1Pk antigens from a donor with rare p[Tj(a-)] phenotype. Methods Peripheral blood mononuclear cells (PBMCs)of an O...

Incidence of adverse transfusion reactions in Chinese children: a meta-analysis

Objective To systematically evaluate the incidence of adverse transfusion reactions in Chinese children, so as to provide scientific basis for prevention and early intervention. Methods Literature databases such as PubMe...

Download PDF file
  • EP ID EP738672
  • DOI 10.13303/j.cjbt.issn.1004-549x.2023.10.021
  • Views 48
  • Downloads 0

How To Cite

Lijuan YANG, Yan HU, Yajuan WU, Li ZHANG, Liping LIU, Tao PENG, Xinyu GAN (2023). Platelet-rich plasma collection and preparation: a retrospective analysis of 256 cases. Chinese Journal of Blood Transfusion, 36(10), -. https://europub.co.uk/articles/-A-738672