Power Quality Improvement Using Dynamic Voltage Restorer

Abstract

One of the important in a power system study is a power quality improvement. It will be important now due to preface the discrete industrial devices and sensitive loads. The main issues in a power quality are voltage sags and swells at the distribution side. There are many different methods available to defect voltage sags and swells; the most popular methods is DVR (Dynamic Voltage Restorer). The DVR is a series compensating device, it is mainly used in low voltage and medium voltage application. The new configuration of DVR has been proposed using PI (Proportional Integral) -controller and PID (Proportional Integral Derivative) -controller and also THD values of PI (Proportional Integral) and PID (Proportional Integral Derivative) controllers are compared and it is conclude that total THD in PID (Proportional Integral Derivative) controller is better than PI (Proportional Integral) controller, which compensates voltage sags and swells during a single phase fault. Simulation results are carried out with MATLAB/SIMULINK to verify the performance of the proposed model.

Authors and Affiliations

Sureshkumar K, Vasanthamani S, Mariammal M, Raj S, Vinodkumar R. L

Keywords

Related Articles

Shape and Size Dependent Electronic Properties of GaAs/AlGaAs Quantum Dots

We have theoretically investigated the effect of shape anisotropy and size on electronic structure of GaAs/AlGaAs quantum dots (QDs). The quantum dot is modeled by anisotropic parabolic confinement potential in the plane...

Effect of Dimension & Material Composition on Transmission Coefficient and Tunneling Current of Double Quantum Barrier Structure with Band Nonparabolicity

Transmission coefficient, eigen states and tunneling current density of a potentially symmetric quantum double barrier structure has been numerically computed using transfer matrix technique for qualitative analysis of r...

Design and Implementation of Op-Amp Based Low-Power CMOS Bandgap Voltage Reference with Minimum Supply oF 0.8-V 

A low power voltage source is generated by altering the device size in existing topology has been presented. Bandgap voltage reference is generated by combination of start-up, supply independent, operational amplifier (O...

Voltage Collapse Proximity Indicator based Placement and Sizing of Static VAR Compensator using BAT Algorithm to Improve Power System Performance 

 Power systems are becoming increasingly more complex due to the interconnection of regional system and deregulation of the overall electricity market. At present owing to the increase in power demand, power system...

Active Power Control in Wind Driven Variable Speed Squirrel-Cage Induction Generator

This paper describes active power control in a grid connected variable speed wind electric generation system (WEG) using squirrel cage induction machine. The chosen variable speed WEG system consists of a wind turbine, s...

Download PDF file
  • EP ID EP587658
  • DOI 10.9756/BIJPSIC.9002
  • Views 135
  • Downloads 0

How To Cite

Sureshkumar K, Vasanthamani S, Mariammal M, Raj S, Vinodkumar R. L (2019). Power Quality Improvement Using Dynamic Voltage Restorer. Bonfring International Journal of Power Systems and Integrated Circuits, 9(1), 1-4. https://europub.co.uk/articles/-A-587658