Radiographic evaluation of the results of total hip arthroplasty with the cementless Zweymüller endoprosthesis

Journal Title: Ortopedia Traumatologia Rehabilitacja - Year 2010, Vol 12, Issue 4

Abstract

AbstractBackground Cementless endoprostheses include the Zweymüller endoprosthesis. Extensive clinical and radiological investigations were carried out in the Department of Orthopaedics and Traumatology of the University of Medical Sciences in Poznań in 180 patients who had received this endoprosthesis between 1995 and 2004.Material and Methods The study group was composed of 180 patients (252 hips), out of whom 138 patients (193 hips) had been operated on due to primary (idiopathic) degenerative changes and 42 patients (59 hips) had needed treatment on account of degenerative changes secondary to developmental hip dysplasia and hip joint dislocation. The mean duration of post-operative follow-up was 6 years in patients with primary degenerative changes and 7 years in patients with secondary degenerative changes. The patients were also divided into two groups according to the length of post-operative follow-up. The first group, evaluated after a follow-up of more than 10 years, was composed of 31 hips, whereas the second group, with a follow-up of up to 10 years after the surgery, comprised of 221 hips. We evaluated anteroposterior hip joint radiographs taken before the surgery, during the follow-up and at the final examination and, additionally, axial hip radiographs taken on the first post-operative day and lateral radiographs of the femur and the hip joint taken at the final examination. The radiographic evaluation was carried out according to the recommendations of the Hip Society.Results There was no radiographic evidence of implant loosening among the 180 patients. In the group of post-dysplastic hips, the inclination angle of the acetabular component was 29-52° (mean: 40.2°) and the acetabular opening angle was 0-21° (mean: 7.9°). The stem was valgus-oriented in 9 hips, varus-oriented in 11 hips and neutral-oriented in 39 hips. In the group of patients with primary degenerative changes the inclination angle of the acetabular component was 29-65° (mean: 42.5°) and the opening angle was 0-32° (mean: 8.9°). The stem was valgus-oriented in 12 cases (6.3 %), varus-oriented in 43 cases (22.6%) and neutral-oriented in 138 cases (71%). There were no statistically significant differences between the group of patients treated due to idiopathic degenerative changes and those treated on account of post-dysplastic patients as well as between the groups divided according to the length of the follow-up as regards the position, the inclination and opening angle of the acetabular component, and the position of the stem.Conclusions The Zweymüller Alloclassic endoprosthesis provides good stability of the acetabular component and the stem in the treatment of both primary and post-dysplastic degenerative changes. The Zweymüller stem provides good conditions for the integration of bone surface with the endoprosthesis, while the acetabular component facilitates the remodelling of the bone surrounding the implant.

Authors and Affiliations

Krzysztof Pietrzak, Zbigniew Piślewski, Wojciech Strzyżewski, Andrzej Pucher, Wiesław Kaczmarek

Keywords

Related Articles

Stabilność siedzenia u dojrzałych szkieletowo pacjentów ze skoliozą w przebiegu przepukliny oponowo - rdzeniowej

Streszczenie Wstęp. Celem pracy jest ocena wpływu stabilności siedzenia dojrzałych szkieletowo pacjentów na ich jakość życia i sprawność fizyczną. Określono także związek jakości siedzenia ze stopniem skrzywienia kręgosł...

Radiological diagnostic of lumbar spondylolysis

Summary. Spondylolysis involves disruption of the bone structure at the vertebral arch at the isthmus. Various methods are utilized in diagnosing spondylolysis, such as plain radiography, computed tomography (CT), magnet...

Modified Colzi method in the management of established Volkmann contracture - the experience of Trzebnica Limb Replantation Center (preliminary report)

Background: “The terrible disability of irreversible ischaemic flexion contracture of the metacarpi and digits known as Volkmann’s contracture can be avoided in the vast majority of cases, but never completely cured” (M....

Ocena wyników leczenia pacjentów po endoprotezoplastyce stawu kolanowego u chorych ze skazami krwotocznymi

Wstęp. Jednym z powikłań u chorych z wrodzonymi skazami krwotocznymi jest występowanie zaawanso­wanej artro­patii krwotocznej. Celem tego badania była ocena wyników leczenia po pierwotnej endoprotezo­plastyce stawów kola...

Interrater and intrarater reliability of lumbar spine magnetic resonance assessment of military aircraft pilot candidates

AbstractIntroduction. The development of diagnostic imaging facilitates evaluation of spinal anatomy, but there is no full correspondence between morphologic and pathologic changes observed in radiographic studies and cl...

Download PDF file
  • EP ID EP57026
  • DOI -
  • Views 56
  • Downloads 0

How To Cite

Krzysztof Pietrzak, Zbigniew Piślewski, Wojciech Strzyżewski, Andrzej Pucher, Wiesław Kaczmarek (2010). Radiographic evaluation of the results of total hip arthroplasty with the cementless Zweymüller endoprosthesis. Ortopedia Traumatologia Rehabilitacja, 12(4), 310-319. https://europub.co.uk/articles/-A-57026