REINFORCING OF HISTORICAL CEILING BEAMS IN THE SHEAR ZONE

Journal Title: Structure and Environment - Year 2015, Vol 0, Issue 4

Abstract

The article discusses the issues concerning rehabilitation and strengthening of wooden beams in historical naked ceilings in their support area. The causes and effects of the damage in the wooden beams shear zones have been presented. Traditional methods of reinforcing beams along with the examples of their application have been shown. Moreover, modern methods of shear zone rehabilitation as proposed in the literature have been presented. What is more, the article also discusses the proposals of the research program with regard to technological solutions for reinforcing of historical ceiling beams in the shear zone, which will be carried out in the laboratories of the Kielce University of Technology.

Authors and Affiliations

Elżbieta Piotrowicz

Keywords

Related Articles

THE COMPARATIVE ANALYSIS OF COMPUTATIONAL METHODS FE AND FD ON THE EXAMPLE OF THE MEMBRANE SURFACE STRUCTURE

The paper contains comparison of FEM and FDM applied in membranes. Innovative element of this calculation method includes replacing a membrane with a framed structure [1]. Sample membranes were tested by two methods, aft...

ARCHITECTURE-&-BUILDING SYSTEMS IN CIVIL CONSTRUCTION

The article deals with the role of Architecture-&-Building systems in Residential and Public Construction. The concept and definition of the Architecture-&-Building systems are determined and reviewed. The structural mod...

EFFECT OF THE ADDITION OF ASH FROM THE INCINERATION OF SEWAGE SLUDGE ON THE PROPERTIES OF CEMENT SLURRIES

The increase of quantity of ash from the combustion of sewage sludge will need to look for new methods of disposal. One method is to use sewage sludge ash as a partial substitute for cement. The oxide composition of the...

CEILING DAMAGE DUE TO SWELLING OF SLAG AGGREGATE IN TERIVA CONCRETE FILLER BLOCKS

The paper reports an example of damage to a Teriva floor slab system. The bottom section of the concrete filling block and the ceiling plasterwork broke away. No symptoms were observed to indicate excessive deformation a...

THE EVALUATION OF THE EFFECT OF CHALCEDONY DUST ON THE REACTION OF ALKALIS WITH REACTIVE AGGREGATE IN CEMENT MORTARS

Chalcedony dust can be used as a mineral additive in cements and concretes. This material can act as a pozzolan and prevent the expansion caused by the alkali-silica reaction. The paper presents the examination of cement...

Download PDF file
  • EP ID EP195365
  • DOI -
  • Views 66
  • Downloads 0

How To Cite

Elżbieta Piotrowicz (2015). REINFORCING OF HISTORICAL CEILING BEAMS IN THE SHEAR ZONE. Structure and Environment, 0(4), -. https://europub.co.uk/articles/-A-195365