Reliability of COP Measures in Healthy and Low Back Pain Subjects During a Dynamic

Journal Title: Ergonomics International Journal - Year 2017, Vol 1, Issue 3

Abstract

Study design. A test–retest design. Objectives: To study the reliability of the postural stability measures during whole body dynamic conditions in healthy and low back pain (LBP) subjects. Summary of Background Data: Postural control is an essential prerequisite for dynamic motions such as lifting, lowering, and repetitive trunk bending tasks. Test retest reliability of center of pressure (COP) measures is well documented in static conditions but such results may not be applicable to dynamic conditions. To the authors knowledge this has not been investigated in dynamic conditions. Methods: Twenty four subjects (12 healthy and 12 LBP) performed repeated trunk bending in two different conditions of high and low speed in sagittal plane. All measurements were repeated and recorded with an interval of 7-10 days later. COP data were used to calculate standard deviation of amplitude, standard deviation of velocity in anterior-posterior and medial-lateral directions, mean total velocity and path length. Relative reliability was assessed using intra class correlation coefficient (ICC) and absolute reliability using standard error of measurement (SEM), minimum detectable change (MMDC) and coefficient of variation (CV). Results: Results in both groups revealed that mean total velocity and standard deviation of amplitude in anteriorposterior direction have an acceptable good to an excellent reliability with ICC range of 0.61-0.89. In healthy group the rest of others parameters also demonstrated an acceptable good to excellent reliability (range 0.6-0.97). In LBP subjects, in addition to standard deviation of amplitude in anterior posterior direction and mean total velocity, standard deviation of velocity in A-P in high pace condition also showed good reliability (ICC=0.69). Conclusion: Mean total velocity and standard deviation of amplitude in anterior-posterior direction are suggested as a good reliable parameter to use for evaluation postural stability in dynamic situations such as lifting and complex trunk movement.

Authors and Affiliations

Mokhtarinia HR*, Kahrizi S, Sanjari MA and Parnianpour M

Keywords

Related Articles

The Impact of the Ambient Conditions on the Desire to Stay

Virtual environments (VEs) technology applied in web shops provided a 3D perspective to customers for more real sense on goods and shopping environment. A sense of presence is one of the critical components required by...

The Art of Spatial Flexion in Ancient Indian Sculpture

The ancient sculptural tradition of INDIA has a significant characteristic. The images, whether they are in seated, standing or reclining postures, are invariably composed in a manner that reflects the grace of dance mo...

The Violence Risk's Management and the Competent Act

The article aims to show the work of nursing technicians in psychiatric patient care in a crisis care unit, revealing the difficulties found and the strategies built to meet the operational needs for the development of...

Residential Building PM2.5 Pollution Control from an Ergonomic and Energy Conservation

PM2.5 pollution has become a big problem in China due to rapid industrialization and high energy consumption. This critical review focuses on current research on PM2.5 particle matter, and provides an insight from ergon...

Ergonomic Assessment of Mental Workload in Higher Education. Effects of Education System on Student’s Workload Perception

Adaptation to the European Higher Education Area (EHEA) has meant a significant change in the workload of students. The main objective of this study is to evaluate and compare the perception of the workload of adapted a...

Download PDF file
  • EP ID EP746507
  • DOI -
  • Views 3
  • Downloads 0

How To Cite

Mokhtarinia HR*, Kahrizi S, Sanjari MA and Parnianpour M (2017). Reliability of COP Measures in Healthy and Low Back Pain Subjects During a Dynamic. Ergonomics International Journal, 1(3), -. https://europub.co.uk/articles/-A-746507