Abstract

The resistance of traditional resistor-capacitor leakage absorption circuit of high-frequency transformer was used to dissipate leakage energy, which leads to the low convertor's efficiency. In this paper, an energy buffer feedback unit based on Flyback converter was proposed to deal with leakage inductance of high-frequency transformers. In addition, the topology and working process of the energy buffer feedback unit were analyzed, and the experimental platform was built. The result shows that when switch tube is turned off, the proposed circuit can not only suppress the transformer leakage inductance resonance voltage spike within1. 2 times of the turn-off voltage, but also effectively utilize the absorbed leakage inductance energy.

Authors and Affiliations

Zhanpeng LI, Shuhai QUAN, Hongyu ZHANG

Keywords

Related Articles

Sliding Friction and Wear Experiment of Wheel-Rail Materials

Taking the wheel CL60 steel and the rail U71 Mn steel as the research object, the sliding friction wear test of the wheel-rail materials was performed by using the pin-disk friction wear tester under different conditions...

Numerical Research of Cooling Module Aerodynamic Noise

Whether the radiator and other components could be ignored in the noise prediction process of cooling module was difficult to calculate. Firstly,the flow field model of equivalent porous media was made. The large eddy si...

Performance of Hybrid Refrigeration System with an Auxiliary Air-cooled Condenser

In order to solve the problem of the relative low refrigeration efficiency in both of the solar-powered absorption refrigeration and air-cooled electricity-driven compression refrigeration applied in building airconditio...

Rapid Determination of Methanol Content in Base Liquor by Near Infrared Spectroscopy

The near infrared spectroscopy method was used to detect the methanol content in base liquor.The spectral data were processed and the quantitative analysis model of methanol was established by partial least squares.By op...

Fuzzy Controller Design for Nonlinear Systems Under Nonuniform Sampling

The nonuniform sampling fuzzy state feedback control for a class of nonlinear systems satisfying the locally Lipschitz condition was studied. By defining a Lyapunov function dependent on sampling time and using a convex...

Download PDF file
  • EP ID EP469104
  • DOI 10.15926/j.cnki.issn1672-6871.2019.03.008
  • Views 52
  • Downloads 0

How To Cite

Zhanpeng LI, Shuhai QUAN, Hongyu ZHANG (2019). Research on Leakage Induced Energy Buffer Feedback Unit Based on Flyback Converter. 河南科技大学学报(自然科学版), 40(3), 40-45. https://europub.co.uk/articles/-A-469104