Robot-Assisted Navigation System For Percutaneous CT Guidedbiopsies With A Comparison of Conventional Manual Technique
Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2017, Vol 16, Issue 12
Abstract
Objective: To evaluate the performance of a robotic system for CT-guided biopsy in comparison to the conventional manual technique. Materials and methods: Patientsreferred for CT-guided biopsy were randomly assigned to two groups namely, Robot-Assisted Procedure (Group A) and Conventional Procedure (Group B). Procedure duration, dose length product (DLP), accuracyof the needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. Results:All biopsies were successfully performed. Procedure duration and radiation dose were significantly reduced in group A as compared to group B. Accuracy of theneedle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups. Conclusion: Robot-assisted CT-guided biopsy can be performed safely, with high diagnostic accuracy thereby reducing procedure duration and radiation dose in comparison to the conventional manual technique. Key Points: CT-guided biopsy is the main procedure in tumor diagnosis for various body organs. 1 The robotic device facilitates percutaneous needle placement under CT guidance. 2 Robot-assisted CT-guided biopsy reduces procedure duration and radiation dose.
Authors and Affiliations
Dr. Ananda kumar
Efficacy of Intracuff Alkalinized 2% Lidocaine in Reducing Cough, Sore Throat And Hoarseness During Emergence in Smokers Undergoing Laparoscopic Surgery
Background: Cough causes various complications during emergence from general anaesthesia especially in smokers. Objective of the Study: To assess the efficacy of intracuff alkalinized 2% lidocaine as compared to saline i...
Evaluation of fetal weight with respect to placental thickness and gestational age using ultrasonography.
The placental thickness can be a useful sonographic parameter. It tends to gradually increase with gestational age in a linear fashion (~ 1 mm per week) and therefore the thickness in mm can approximate the gestational a...
Effect of one-step polishing systems and bleaching on color of resin composites after staining
Purpose:The aims of this study were to evaluate the effects of OneGloss and PoGo one-step polishing systems and an office-bleaching agent (Ultradent Opalescence Boost PF 40%) oncolor of two nanocomposite resin restorativ...
Right Ileac Fossa Mass: A Case Series
Introduction: A mass in the right iliac fossa is one of the commonest problems encountered in surgical practice, requiring skill to diagnose. A clinical diagnosis is often difficult due to other conditions like obesity a...
Socio Cultural Hurdles in Late Presentation of Primary Amenorrhoea Case Report
This is the report of a late presentation of case of MRKH at 27yrs with coital difficulty. Some of the reasons for late diagnosis of such cases in the face of advanced medical and scientific technology are Social stigm...