Rotor Angle Stability Improvement of DFIG Using Grid Side and Rotor Side Converter Control

Abstract

Wind energy generation with Doubly Fed Induction Generator is dominant one in wind farms. High penetration of DFIG is creating more instability in rotor side and grid side. Applying a set of optimized control parameter, the stability can be further enhanced. In this paper variable load condition rotor angle stability of the DFIG is improved by Grid Side (GSC) and Rotor Side Converter (RSC) control. In DFIG, the frequency of the rotor excitation input, real and reactive powers are modified based on rotor speed and load variation. The simulation result shows the effectiveness and performance of the DFIG with GSCRSC converter control techniques.

Authors and Affiliations

Mathusoothanan. T, Dr. R. Karthik

Keywords

Related Articles

Characterization, Treatment and Disposal of Sludge: A Review

Treatment of industrial and domestic effluent is widely studied topic in the environmental engineering. Various techniques used for the wastewater treatment includes biological, physical and chemical treatments. Most co...

Survey on Data Mining for Increasing Agriculture Productivity

Crop management of certain agriculture region is depends on the climatic conditions of that region because climate can make huge impact on crop productivity. Real time weather data can helps to attain the good crop mana...

Analysis of Liquefaction Prone Area in India and Its Remediation

“Liquefaction” A major cause of structural damage during earthquake. As one the most hazardous event is discussed, certain analysis for soil are to be performed to understand the behavior of soil and its stability towar...

A Study on Marketing Strategy Analysis of Samsung Mobile

This paper present about the marketing strategies of Samsung mobile. Fundamental research was been carried out to understand and identify the attitude of people towards the company. Various factors differing from the av...

A Review on Tube and Shell Heat Exchanger with Elliptical Twisted Geometry

In various engineering applications such as heat exchanger, air conditioning, chemical reactors and refrigeration systems, heat transfer enhancement techniques are popularly used. This paper reviews a multi-objective op...

Download PDF file
  • EP ID EP21690
  • DOI -
  • Views 220
  • Downloads 3

How To Cite

Mathusoothanan. T, Dr. R. Karthik (2016). Rotor Angle Stability Improvement of DFIG Using Grid Side and Rotor Side Converter Control. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 4(3), -. https://europub.co.uk/articles/-A-21690