Study of H2/N2Mixture Plasma Treatment on the AISI 1045
Journal Title: Journal of Nuclear Physics, Material Sciences, Radiation and Applications - Year 2017, Vol 5, Issue 1
Abstract
In the present work, we analyzed the effect of the plasma treatment of 80% H2/20% N2 mixture plasma over the AISI 1045 steel. To produce the plasma, an AC discharge of 0.1 A at 350 V was produced at a total pressure of 3.0 Torr. The mixture plasma was analyzed using optical emission spectroscopy (OES), in the wavelength range of 200 to 1100 nm. The principal species observed in the plasma were NH, N2, N2 +, H2, and Hα. The electron temperature and ion density have been measured using a double Langmuir probe. The samples of steel were treated by plasma at different discharge times, between 3 and 12 h, at the same pressure and AC parameters (0.1 A and 350 V). The treated samples were characterized using X-ray analysis, finding the phases gamma and epsilon of iron nitride. The thickness of the nitrided layers was measured using a scanning electron microscope (SEM). From the images obtained, it is possible to appreciate the interphase between the nitrided layer and the steel matrix. The relationship between the morphology of the surface of nitrided steel and the wetting was analyzed by measuring the contact angle between the surface and a drop of 5 µL of distilled water. The contact angle of the drop increased with the increase of plasma treatment time. The control sample without treatment presented a smaller angle, and after the treatment the surfaces of the steel became hydrophobic. This may be related to the morphology change of the steel surface produced by plasma treatment.
Authors and Affiliations
E. Pardo L. , J. G. Gonzalez-Rodriguez, B. Campillo, F. Castillo, O. Flores, H. Martínez
Response to Neutrons and γ-rays of Two Liquid Scintillators
UltimaGoldTM AB and OptiphaseTrisafe are two liquid scintillators made by Perkin Elmer and EG & G Company respectively. Both are commercially promoted as scintillation detectors for α and β particles. In this work, t...
The Dependence of Surface Diffuseness Parameter on N/Z Ratio of The Fusion of Neutron-Rich Colliding Nuclei
Surface diffuseness parameter used in Woods-Saxon form of potential have been extracted from a large number of experimentally studied neutron-rich fusion cross sections at near barrier energies. The results of our system...
Measurements of Neutrons In A Mixed GammaNeutron Field Using Three Different Types of Detectors
A linear electron accelerator for medical use is a device for the treatment of tumors by collimated beams of electrons and/or photons. These accelerators are devices that employ electromagnetic waves of high frequency, t...
Enhancement in the Photoluminescence Properties of SiO2:Ge Embedded in a Polymeric Matrix
Polymer films of styrene butadiene copolymer (SBC) mixed with SiO2:Ge powder were successfully obtained by the drop casting method. The SBC concentration (in chloroform solution) was 10%w/v and the SiO2:Ge powder was mix...
Application of a CdTe Detector for Measurements of Mammographic X-ray Spectra
This work aims to characterize mammographic x-ray beams incident and transmitted by breast phantoms (from 0 to 45 mm) composed from known proportion of glandular and adipose tissue-equivalent materials. This study was pe...