Surgical treatment of endocarditis with an aortic homograft
Journal Title: Polski Przegląd Kardiologiczny - Year 2006, Vol 8, Issue 4
Abstract
Introduction: Endocarditis is still a relevant disease. An aortic valve replacement with mechanical prosthesis is a most common surgical treatment. In some patients the disease spreads into the valve annulus or periannullar abscess can develop. In such cases an optimal treatment method seems to be implantation of an aortic homograft (AH) which is composed only of biological tissues and does not contain any artificial materials. Aim of study: The aim of the study was to asses the early and long-term results surgical treatment aortic valve endocarditis with using aortic homograft implantation inourclinic. Material and methods: From 1991 to 2005, in the I Department of Cardiosurgery, Instituteof Cardiology, Warsaw, Poland, a total number of 37 patients (8 women and 29 men) ranging in age from 15 to 66 years (mean age 37 years), under went AH implantation due to aortic valve endocarditis. The indications for using AH were established due to endocarditis of aortic annulus orperiannular abscess. In primary operation AH was implanted in 20 patients, 17 patients had pervious cardiac surgery. In one case due to renal failure patient required to have hemodializes performed before operation. In two patients with congenital heart defects pulmonary homografts were inserted in right outflow ventricular tract additionally. In all the patients implantation technique was "root replacement". Results: Perioperative mortality was 5.4% (due to multiorgan failure). There were two late deaths (5.4%) related to aortic valve endocarditis of mycotic etiology. The reoperation was necessary in 2 cases: in 1 patient due to homograft dissection and in another one due to reinfection and homograft valve insufficiency. The group of 31 patients stays in longtime observation ranged from 2 months to 15 years (average follow up of 68 months). Symptomatic improvement insurvivors was excellent. According to clinical criteria, all the followed up patients were in NYHA functional class I. Echocardiography demonstrated homografts with no degenerations ignsor significant transvalvular gradients, trivial to mild aortic regurgitation is observed. Conclusions 1. Aortic homograft implantation due to endocarditis can be performed with low perioperative risk. 2. Homograft AVR is safe and produces good early and longterm results with low mortality. 3. The AH implantation is excellent therapeutic option especially for active aortic valve endocarditis involving aortic ring.
Authors and Affiliations
Mariusz Kuśmierczyk, Jacek Różański, Krzysztof Kotliński, Hanna Siudalska, Katarzyna Barańska, Piotr Hoffman, Andrzej Biederman
Włókniak serca i zespół preekscytacji - czy ten pacjent wymaga diagnostyki inwazyjnej?
Pierwotne guzy serca w materiale autopsyjnym stwierdza się w 0,0017-0,028% przypadków, wśród których włókniaki występują u mniej niż u 5%. Wyniki leczenia operacyjnego włókniaków o przebiegu objawowym są bardzo dobre. Ni...
Czy płeć wpływa na terapię i rokowanie w ostrych zespołach wieńcowych?
Ostre zespoły wieńcowe (o.z.w.) obejmują najcięższe postaci choroby wieńcowej, wymagające kompleksowego postępowania. Panuje przekonanie, że istnieją znaczące różnice między kobietami i mężczyznami w strategii diagnostyc...
Wartość wstępnego elektrokardiogramu w ocenie obszaru ostrego niedokrwienia w zawale mięśnia sercowego ściany dolnej
Wprowadzenie: W ostatnich latach zwrócono uwagę na zależność obrazu elektrokardiograficznego (EKG) od angiograficznej lokalizacji zawału. Pewne cechy zapisu EKG pozwalają w przybliżeniu określić czy naczyniem dozawałowym...
Dynamika zmian parametrów sygnału przedsionkowego i synchronizacji przedsionkowo - komorowej w stymulacji VDD z pojedynczą elektrodą
Wprowadzenie: VDD jest alternatywnym w stosunku do DDD systemem stymulacji u chorych z zaawansowanymi zaburzeniami przewodzenia przedsionkowo -komorowego (AV) i prawidłową funkcją węzła zatokowo -przedsionkowego (SA...
Przenośne aparaty echokardiograficzne. Co nowego?
Pierwsze doniesienie w literaturze medycznej na temat zastosowania przenośnego aparatu echokardiograficznego (hand-carried cardiac ultrasound - HCU) miało miejsce w 1978 r. Jednak dopiero w ostatnich latach rozwój techno...