THD ANALYSIS IN THREE PHASE-THREE LEVEL VSI WITH MPPT TRACKER AND SEPIC CONVERTER FOR SOLAR PV ARRAY

Journal Title: JOURNAL OF ADVANCES IN CHEMISTRY - Year 2016, Vol 12, Issue 16

Abstract

This paper deals with the analysis of total harmonic distortion in three phase three level voltage source inverter (VSI) for the solar photovoltaic array. The Voltage source inverter as used in high power applications here we are using for the Renewable Energy as Application. The result for the Voltage Source Inverter will be quasi square wave or square wave. The Harmonics will be high if we are using the low level inverter. The 1200 or 1800 are the two modes of operation for voltage source inverter and its choose based upon its application. The MPPT technique is used to get the maximum power from the Solar PV. The SEPIC converter is DC-DC converter in which it can operates either buck or boost modes and it eliminates the ripples by using the filter. In order to improve the efficiency the SEPIC and Perturb and Observe Technique is used. The focus of the paper is to analyze and reduce the Total Harmonic Distortion with the MPPT Technique and DC-DC converter and its connected to the Grid. The simulation results for the paper and the THD values are calculated for voltage source inverter (VSI) are given below [13], [14].

Authors and Affiliations

S. K. Saranya, T. Gowtham Raj, P. Ranjani

Keywords

Related Articles

Validation of multi-machine and single-machine equivalent models for wind farm transient stability studies

Stability study of power system with wind farm is challenging task due to collection of system data, computation burden in case of system order and long simulation time. An aggregated representation of fixed speed wind t...

Preparative Purification of Delphinidin 3-0-sambubioside from Roselle (Hibiscus sabdariffa L.) Petals by fast Centrifugation Partition Chromatography

Delphinidin 3-0-sambubioside, a Hibiscus anthocyanin, was isolated from MeOH/TFA dried flower of H. sabdariffa. Its purification on preparative scale was obtained by centrifugal partition chromatography (CPC) using the t...

Synthesis, structure and characterization of a new noncentrosymmetric Zn(II) complex with the 2-amino-5-chloropyridine ligand (AClPy)

A new noncentrosymmetric Zn(II) complex with the monodentate ligand 2-amino-5-chloropyridine (AClPy), ZnCl2(C5H5ClN2)2, has been prepared at room temperature and characterized by single crystal X-ray diffraction, 13C CP-...

THE APPLICATION OF AMINO AND HYDROXYETHYL IMIDAZOLINES OF PETROLEUM ACIDS AS MULTIFUNCTIONAL ADDITIVES FOR DIESEL FUEL

In this research, the influence of amino- and hydroxyethyl imidazolines of petroleum acids on the antistatic property and lubricity of diesel fuel has been studied. The researches illustrated that when the boiling point...

HYBRID CLASSIFICATION SCHEMES FOR HEART MURMUR DETECTION TO ASSIST PHONOCARDIOGRAM BASED SIGNAL ACQUISITION

The main contribution of this paper has been to introduce nonlinear classification techniques to extract more information from the PCG signal. Especially, Artificial Neural Network classification techniques have been use...

Download PDF file
  • EP ID EP652941
  • DOI 10.24297/jac.v12i16.694
  • Views 183
  • Downloads 0

How To Cite

S. K. Saranya, T. Gowtham Raj, P. Ranjani (2016). THD ANALYSIS IN THREE PHASE-THREE LEVEL VSI WITH MPPT TRACKER AND SEPIC CONVERTER FOR SOLAR PV ARRAY. JOURNAL OF ADVANCES IN CHEMISTRY, 12(16), 4895-4901. https://europub.co.uk/articles/-A-652941