This paper presents a novel transient based protection for High Voltage Direct Current (HVDC) system. Behaviour of the HVDC system during internal and external fault is studied. Variation of transient energy and the relation between various parameters of the line are analysed during each fault. Based on the transient protection principle is developed. Transient energy can be obtained by measuring the voltage and current at the two terminals of the line. Identification of internal fault and external fault can be done correctly and quickly from the calculated value of transient energy. The transient current can be analysed to find out the type of DC line fault. The test system is modelled and analysed for various faults using MATLAB - SIMULINK package based on CIGRE HVDC benchmark system.

Authors and Affiliations

Vijayal V, Krishnamoorthi K, Sasikumar S

Keywords

Related Articles

Design of Automatic Seed Feeding Machine

The present review provides brief information about automatic seed feeding machine. The basic objective of seed feeding machine is to inseminate seeds at a required depth with certain spacing and covering the seeds with...

Determination of cloud adoption factor and Subordinate Virtual Cloud mechanism to overcome the performance issues in bigdata

Any large unstructured data sets with sizes beyond the ability of the software tools to manage and process within a tolerable elapsed time is rightly observed as bigdata. Cloud computing is delivery of on demand computi...

A Study on Workers Participation in Management

most important outcome of great industrial revolution is the change in the approach of management towards workers. The workers no more considered as machines their feeling ambition and emotions have been duly recognized...

Short Term Load Forecasting Using Moving Averages

Electricity is an essential part of our life and without this nothing is possible an accurate and efficient Short term load forecasting plays a vital role for economic operational planning of both regulated power system...

An Automated Non-Invasive Blood Glucose Estimator and Infiltrator

This paper presents design and working of a microcontroller based non-invasive blood glucose estimator and an automated insulin injector for worst-case automatically. The emergence of this concept is to overcome the inv...

Download PDF file
  • EP ID EP23831
  • DOI http://doi.org/10.22214/ijraset.2017.4125
  • Views 251
  • Downloads 6

How To Cite

Vijayal V, Krishnamoorthi K, Sasikumar S (2017). The Identification of Fault in HVDC Transmission Line using Transient Protection Scheme. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(4), -. https://europub.co.uk/articles/-A-23831