Abstract
This paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered criteria. For each of the first three, economic criteria, partial assessment measure was calculated using the normalisation method. For each of the other five, technical criteria, we developed a relative measure of the distance of the indicator from the threshold (e.g. the ratio of voltage drop in power supply line nodes in relation to its permissible value). This algorithm rejects variants whereby the thresholds set for partial criteria were exceeded in the time period of load/micro-generation source connection. The method was implemented in an MS Excel workbook and used to analyse complex problems of load or microgeneration source connections.
Authors and Affiliations
Paweł Bućko, Jerzy Buriak, Krzysztof Dobrzyński, Marcin Jaskólski, Piotr Skoczko
Operation of a BC50 Cogeneration Unit of a CHP Plant in an Isolated Island System
In a paper presented at the previous APE ‚13 conference [1] results of a concept of separating an island system with a BC50 thermal unit in VEOLIA ENERGY Poznan ZEC SA’s power plant (hereinafter ECII Karolin) were presen...
Increasing Generation Capacity by Power Unit Upgrades
To ensure Poland’s energy security in the coming years will require increasing the power system’s generation capacity while at the same time improving both the efficiency of electricity generation and its use [1, 2]. One...
Electricity Distribution Effectiveness
This paper discusses the basic concepts of cost accounting in the power industry and selected ways of assessing the effectiveness of electricity distribution. The results of effectiveness analysis of MV/LV distribution t...
Resonant Conditions in a Node with an SVC Compensator
The primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery...
Operational Parameters of Low Power ORC Biomass Plant
This paper describes a power plant with electrical/thermal capacity of 750 kW/3.4 MW launched in February 2015 by a private investor in Żory, Poland. The ORC Organic Rankine Cycle technology used there enables turbine op...