THE SELECTION OF PRELOAD IN ANGULAR CONTACT BALL BEARINGS ACCORDING TO THE DURABILITY CRITERION

Journal Title: Tribologia - Year 2018, Vol 277, Issue 1

Abstract

The regulation of the preload of angular contact ball bearings is mentioned in specialist literature, but only as a practical activity carried out based on experience, still without selection methodology. At present, there exists no widely accessible method of this load selection. Neither the literature on the subject nor catalogues of bearings producers give recommendations for the selection of this parameter, which is most often perceived intuitively. Still, it is known that its wrong selection can have a catastrophic influence on the durability of bearings. In consequence, there exists a problem of the accurate choice of preload (i.e. of such a preload that the durability of bearings will not be significantly decreased). The aim of the study is to determine the maximum preload in angular contact ball bearings by the criterion of durability, taking into account shaft flexibility and the flexibility of bearings. In order to determine a general influence of preload on fatigue life of bearings, numerous calculations were made for different locations of the plane of load.<br/><br/>

Authors and Affiliations

Jarosław KACZOR, Andrzej RACZYŃSKI

Keywords

Related Articles

Wpływ dodatku modyfikującego AR na właściwości tribologiczne ekologicznych smarów plastycznych

W publikacji przedstawiono wyniki badania wpływu dodatku polimerowo-krzemionkowego na właściwości smarne wybranych kompozycji smarowych. Do modyfikacji smarów plastycznych wytworzonych na bazie mineralnej oraz silikonowo...

WPŁYW WYBRANYCH CZYNNIKÓW NA PROCES ZUŻYCIA W RUCHU OSCYLACYJNYM

Na powierzchni elementów współpracujących w ruchu ślizgowym zachodzą złożone procesy zużywania tribologicznego, które podczas bezpośredniego kontaktu metal–metal doprowadzają do powstania ubytku objętościowego tych eleme...

ANALYSIS OF THE LOAD-CARRYING CAPACITY OF A HYDRODYNAMIC WATER-LUBRICATED BEARING IN A HYDROELECTRIC POWER PLANT

The paper presents an analysis of the load-carrying capacity of a historic hydrodynamic water-lubricated radial bearing of an unconventional segment design installed in the Braniewo Hydroelectric Power Plant. The aim of...

CARBIDE LAYERS PRODUCED IN VACUUM CHROMIZING PROCESS ON STEEL SURFACE COVERED WITH NICKEL ALLOYS CONTAINING CARBIDE-FORMING ELEMENTS

In this paper duplex layers of the CrC+(Ni-W), the CrC+(Ni-Mo) and the CrC+Ni type produced on tool steel surface, in combined galvanic and vacuum chromizing processes, have been investigated. Studies of layers thickness...

EVALUATION OF THE LUBRICATION EFFICIENCY OF GREASES ACCORDING TO CRITERION OF WEAR EXPERIMENTALLY DETERMINED AT VARIABLE VALUES OF MOTION PARAMETERS

The results of tribological investigations into the lubrication efficiency of greases in steel sliding pairs working in mixed friction conditions are presented. The lubrication efficiency was evaluated according to the c...