Abstract

Introduction. Perianal abscesses are not uncommon pathology in children, while the ethiopathology of perianal fistula still need to be determined. Surgical treatment involves abscess incision and evacuation usually without the need for imaging. Transperineal ultrasound (TPUS) and endorectal ultrasound (ERUS) enable the assessment of the distribution and penetration of perianal abscesses and fistulas.Aim. Aim of this study is the evaluation of usefulness of the intrasurgical TPUS and H2O2 enhanced endosonography in the assessment of the distribution and penetration of perianal abscesses and fistulas in children.Material and methods. US examination was performed in 9 children (aged 2 month to 8 years old) with perianal abscess and fistula. The examination was performed before abscess incision in order to assess its distribution, as well as after surgical incision, and H2O2 injection to visualise fistulous tract. The US examinations were performed with the use of Philips iU22 ultrasound scanner with high frequency transducers (L 12-5 MHz and L 15-7 MHz) and BK-Medical Profocus ultrasound scanner with high frequency (16-9 MHz) 360 degrees rotational transducer with automatic 3D data acquisition (type 2050).Results. The measurements of perianal abscesses and fistulas in all patients taken at B-mode US were statistically significantly lower than that ones taken after H2O2 injection. H2O2 enhanced US examination enabled precise assessment of anatomical relations between abscesses and fistulous tracts towards external and internal anal sphincters influencing widening of the extent of surgery. Surgical treatment was successful in all patients. No recurrence was noticed in short time follow-up.Conclusions. Transperineal and transanal US with the use of high frequency transducers and H2O2 injection enabled precise assessment of the distribution of perianal abscesses and fistulas, and had an impact on the surgery extent.

Authors and Affiliations

Agnieszka Brodzisz, Czesław Cielecki, Paweł Nachulewicz

Keywords

Related Articles

Stany przednowotworowe sromu – przegląd piśmiennictwa i doświadczenia własne

Wstęp. Stany przednowotworowe sromu podobnie jak zmiany przednowotworowe szyjki macicy początkowo klasyfikowano jako VIN 1, VIN 2 i VIN 3. Obecnie na podstawie zmian histopatologicznych przyjęto podział na uVIN i dVIN. O...

Recurrence AT FSGS in renal transplant

Recurrence of focal segmental glomerular sclerosis in renal transplant recipient usually manifests as massive proteinuria within hours to days after transplantation. Reccurrence of FSGS is recognized to be a disease asso...

Transforming growth factor β1 as an indicator of the progression of chronic viral hepatitis

Transforming growth factor b1 (TGF b1) is main cytokine responsible for progression of fibrosis in chronic liver disease. Factors having impact on progression in chronic viral hepatitis (cvh) are not clearly identified.T...

A brief history of the artificial oesophagus

Despite the progress in diagnostics procedures, oesophageal cancer is often diagnosed in its late stages. Because of the advanced stage at which it usually presents, treatment of carcinoma of the oesophagus is just palli...

Renal failure in a patient with multiple myeloma as thrombotic microangiopathy after gastrointestinal infection

Multiple myeloma despite new drugs is recognized as an incurable disease. Lymphoid neoplasms are characterized by deep secondary immunodeficiency.<br>In patients with a diagnosis of multiple myeloma, immuno...

Download PDF file
  • EP ID EP54767
  • DOI -
  • Views 114
  • Downloads 0

How To Cite

Agnieszka Brodzisz, Czesław Cielecki, Paweł Nachulewicz (2013). The use of transperineal ultrasound and endosonography using H2O2 in the diagnosis of perianal abscesses and fistulas in children . Postępy Nauk Medycznych, 26(8), -. https://europub.co.uk/articles/-A-54767